Contrast-enhanced Spiral CT of the Head and Neck ================================================ * Lawrence E. Ginsberg The article by Groell et al (1) concerning contrast injection rates in head and neck CT raises several important issues that deserve further dialogue. I am in complete agreement with the authors that adequate opacification of the cervical vessels is crucial, and a cornerstone of high-quality head and neck CT. Outside studies referred to our institution for interpretation are frequently suboptimal in this regard. There is no mention in the Methods sections of the Groell article of angulation of the gantry so as to avoid the dental fillings found in many patients. In my opinion, this is of critical importance in obtaining a good head and neck CT study and something that is very often overlooked, to the detriment of the examination. The optimal injection rate/volume established by the authors would not work if they were to angle around the fillings. They would run out of contrast material, and therefore I take exception to their conclusions and fear that to adopt them might lead to suboptimal imaging. At the M.D. Anderson Cancer Center we scan as follows: the scans are obtained from inferior to superior (the extra few seconds it takes to get up to the oral cavity is thought to facilitate better delivery of contrast material to those structures and thus better lesion visualization). We start with an initial bolus of 75 cc of 320 mg IV contrast material at an injection rate of 1.5cc/s and begin scanning after a 50-second delay. At the bottom of the dental fillings, we stop scanning and reangle the gantry, a process that takes approximately 60–80 seconds. During this reangling, we give an additional bolus of 50 cc at a rate of 1cc/s. This extra contrast material assures adequate opacification of the vasculature as the upper neck and skull base are scanned. This protocol works very well for us and is quite reproducible. Obviously the iodine dose is higher (40 g vs 30 g), but in order to have good vascular opacification and avoid dental fillings, more contrast material must be administered. ## Reference 1. Groell R, Willfurth P, Schaffler G, et al. **Contrast-enhanced spiral CT of the head and neck: comparison of contrast material injection rates.** AJNR Am J Neuroradiol 1999;20:1732-1736 [Abstract/FREE Full Text](http://www.ajnr.org/lookup/ijlink/YTozOntzOjQ6InBhdGgiO3M6MTQ6Ii9sb29rdXAvaWpsaW5rIjtzOjU6InF1ZXJ5IjthOjQ6e3M6ODoibGlua1R5cGUiO3M6NDoiQUJTVCI7czoxMToiam91cm5hbENvZGUiO3M6NDoiYWpuciI7czo1OiJyZXNpZCI7czo5OiIyMC85LzE3MzIiO3M6NDoiYXRvbSI7czoyMjoiL2FqbnIvMjEvNy8xMzY1LjIuYXRvbSI7fXM6ODoiZnJhZ21lbnQiO3M6MDoiIjt9) * Copyright © American Society of Neuroradiology