Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

Research ArticlePatient SafetyF

Low Kilovoltage CT of the Neck with 70 kVp: Comparison with a Standard Protocol

R. Gnannt, A. Winklehner, R. Goetti, B. Schmidt, S. Kollias and H. Alkadhi
American Journal of Neuroradiology June 2012, 33 (6) 1014-1019; DOI: https://doi.org/10.3174/ajnr.A2910
R. Gnannt
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
A. Winklehner
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
R. Goetti
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
B. Schmidt
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
S. Kollias
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
H. Alkadhi
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

Article Figures & Data

Figures

  • Tables
  • Fig 1.
    • Download figure
    • Open in new tab
    • Download powerpoint
    Fig 1.

    37-year-old male patient with follow-up neck CT for lymphoma at 70 kVp (A, C, E) and corresponding previous CT at 120 kV (B, D, F) at 3 anatomical levels. Note the diagnostic image quality with a higher contrast-to-noise ratio of cervical soft tissues at 70 kVp at all levels.

  • Fig 2.
    • Download figure
    • Open in new tab
    • Download powerpoint
    Fig 2.

    42-year-old male patient with follow-up neck CT for lymphoma at 70 kVp (A) and corresponding previous CT at 120 kVp (B). Sagittal reconstructions of the cervical spine demonstrate more image noise in the lower spine at 70 kVp in comparison to 120 kVp. Corresponding axial images through the lower neck (level of C7) at 70 kVp (C).

  • Fig 3.
    • Download figure
    • Open in new tab
    • Download powerpoint
    Fig 3.

    Measurements of cervical vessel (A) and muscle (B) attenuation, image noise (C), and the calculated contrast-to-noise ratio (D). Mean from both readers was taken for analysis.

Tables

  • Figures
    • View popup
    Table 1:

    Image quality and artifacts of the cervical soft tissues and bones at 70 kVp and 120 kVp

    70-kVp protocol (n = 20)120-kVp protocol (n = 20)P Value*
    Reader 1Reader 2Reader 1Reader 2Reader 1Reader 2
    Image quality: soft tissue
        Overall3.92 ± 1.053.85 ± 1.074.05 ± 0.773.86 ± 0.850.2110.606
        Upper third3.20 ± 1.113.15 ± 1.093.45 ± 0.763.45 ± 0.760.1350.055
        Middle third4.95 ± 0.224.95 ± 0.224.60 ± 0.504.40 ± 0.500.0150.001
        Lower third3.60 ± 0.603.45 ± 0.604.00 ± 0.463.85 ± 0.490.0170.008
    Image quality: bone
        Overall3.89 ± 1.183.51 ± 1.124.33 ± 0.704.19 ± 0.70<0.001<0.001
        Upper third4.35 ± 0.494.30 ± 0.474.42 ± 0.514.16 ± 0.680.5780.414
        Middle third4.50 ± 0.514.45 ± 0.604.84 ± 0.384.68 ± 0.490.2760.058
        Lower third2.75 ± 1.162.65 ± 1.163.74 ± 0.733.74 ± 0.65<0.001<0.001
    Artifacts
        Soft tissue and spine3.95 ± 1.043.70 ± 1.114.20 ± 0.824.03 ± 0.97<0.001<0.001
        Upper third3.15 ± 1.043.05 ± 1.003.55 ± 0.903.25 ± 1.030.5090.09
        Middle third5.00 ± 0.005.00 ± 0.004.95 ± 0.235.00 ± 0.000.330.33
        Lower third3.55 ± 0.693.35 ± 0.494.10 ± 0.453.85 ± 0.490.0020.042
    • ↵* P values comparing 70-kVp and 120-kVp scans in the same 20 patients.

    • View popup
    Table 2:

    Comparison of CTDIvol, DLP, scan length, and effective dose between 70-kVp and 120-kVp CT scans

    70 kVp (n = 20)120 kVp (n = 20)P Value*
    CTDIvol(mGy)7.27 ± 0.9310.79 ± 0.86<0.001
    Scan length (cm)18.32 ± 3.2919.05 ± 1.880.74
    DLP (mGy*cm)144.23 ± 29.90224.60 ± 35.15<0.001
    Eff dose (mSv)0.85 ± 0.181.33 ± 0.21<0.001
    • Note:—DLP is calculated by multiplying the CTDIvol by the scan length in the z-axis. Eff dose indicates effective radiation dose, calculated by multiplying the DLP by mSv*mGy-1*cm-1.11

    • ↵* P values comparing 70-kVp and 120-kVp scans.

PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 33 (6)
American Journal of Neuroradiology
Vol. 33, Issue 6
1 Jun 2012
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Low Kilovoltage CT of the Neck with 70 kVp: Comparison with a Standard Protocol
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
R. Gnannt, A. Winklehner, R. Goetti, B. Schmidt, S. Kollias, H. Alkadhi
Low Kilovoltage CT of the Neck with 70 kVp: Comparison with a Standard Protocol
American Journal of Neuroradiology Jun 2012, 33 (6) 1014-1019; DOI: 10.3174/ajnr.A2910

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Low Kilovoltage CT of the Neck with 70 kVp: Comparison with a Standard Protocol
R. Gnannt, A. Winklehner, R. Goetti, B. Schmidt, S. Kollias, H. Alkadhi
American Journal of Neuroradiology Jun 2012, 33 (6) 1014-1019; DOI: 10.3174/ajnr.A2910
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • ABBREVIATIONS:
    • Materials and Methods
    • Results
    • Discussion
    • Conclusions
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Systematic Radiation Dose Reduction in Cervical Spine CT of Human Cadaveric Specimens: How Low Can We Go?
  • Advantages of 70-kV CT Angiography for the Visualization of the Adamkiewicz Artery: Comparison with 120-kV Imaging
  • Advanced Modeled Iterative Reconstruction in Low-Tube-Voltage Contrast-Enhanced Neck CT: Evaluation of Objective and Subjective Image Quality
  • Low-Tube-Voltage 80-kVp Neck CT: Evaluation of Diagnostic Accuracy and Interobserver Agreement
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • Safety of Intrathecal Gadobutrol in Various Doses
  • Impact of Kidney Function on CNS Gadolinium Deposition in Patients Receiving Repeated Doses of Gadobutrol
  • Contrast-Induced Acute Kidney Injury in Radiologic Management of Acute Ischemic Stroke in the Emergency Setting
Show more Patient Safety

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire