Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

Research ArticlePatient Safety

Radiation Dose for 345 CT-Guided Interlaminar Lumbar Epidural Steroid Injections

A.L. Chang, A.H. Schoenfeld, A.L. Brook and T.S. Miller
American Journal of Neuroradiology October 2013, 34 (10) 1882-1886; DOI: https://doi.org/10.3174/ajnr.A3540
A.L. Chang
aFrom the Department of Radiology (A.L.C., A.H.S., A.L.B., T.S.M.), Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York
bDepartment of Radiological Sciences (A.L.C.), University of California, Irvine, California.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
A.H. Schoenfeld
aFrom the Department of Radiology (A.L.C., A.H.S., A.L.B., T.S.M.), Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
A.L. Brook
aFrom the Department of Radiology (A.L.C., A.H.S., A.L.B., T.S.M.), Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
T.S. Miller
aFrom the Department of Radiology (A.L.C., A.H.S., A.L.B., T.S.M.), Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, New York
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

Abstract

BACKGROUND AND PURPOSE: CT guidance is increasingly being used to localize the epidural space during epidural steroid injections. A common concern is that CT may be associated with significantly higher radiation doses compared with conventional fluoroscopy. The goal of this retrospective study was to determine the average dose-length product and effective dose delivered while interlaminar epidural steroid injections are performed and allow comparison with other modalities.

MATERIALS AND METHODS: A total of 281 patients who had undergone 345 consecutive CT-guided epidural steroid injections of the lumbar spine were evaluated for radiation exposure. The dose-length product for each scan was derived from the CT dose index volume and scan length. Effective dose was then calculated from the dose-length product and a κ coefficient of 0.015. Procedure time was calculated from the PACS time stamp on the scout image to the last CT image of the last image series.

RESULTS: The average dose-length product across all procedures was 89.6 ± 3.33 mGy·cm, which represents an effective dose of 1.34 ± 0.05 mSv. No complications from the procedure were observed, and average procedure time was 8 minutes.

CONCLUSIONS: The use of a stationary table and an intermittent scanning technique allow for short procedures and doses that are significantly lower than those of conventional diagnostic CT scans. Furthermore, because CT dose index overestimates radiation dose in stationary table procedures, the actual radiation dose may be even lower than stated here.

ABBREVIATIONS:

CTDI
CT dose index
CTDIvol
CTDI volume
DLP
dose-length product
ED
effective dose
ESI
epidural steroid injection
  • © 2013 by American Journal of Neuroradiology
View Full Text
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 34 (10)
American Journal of Neuroradiology
Vol. 34, Issue 10
1 Oct 2013
  • Table of Contents
  • Index by author
  • Complete Issue (PDF)
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Radiation Dose for 345 CT-Guided Interlaminar Lumbar Epidural Steroid Injections
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
A.L. Chang, A.H. Schoenfeld, A.L. Brook, T.S. Miller
Radiation Dose for 345 CT-Guided Interlaminar Lumbar Epidural Steroid Injections
American Journal of Neuroradiology Oct 2013, 34 (10) 1882-1886; DOI: 10.3174/ajnr.A3540

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Radiation Dose for 345 CT-Guided Interlaminar Lumbar Epidural Steroid Injections
A.L. Chang, A.H. Schoenfeld, A.L. Brook, T.S. Miller
American Journal of Neuroradiology Oct 2013, 34 (10) 1882-1886; DOI: 10.3174/ajnr.A3540
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • ABBREVIATIONS:
    • Materials and Methods
    • Results
    • Discussion
    • Conclusions
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Radiation Dose Reduction in CT-Guided Spine Biopsies Does Not Reduce Diagnostic Yield
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • Safety of Intrathecal Gadobutrol in Various Doses
  • Impact of Kidney Function on CNS Gadolinium Deposition in Patients Receiving Repeated Doses of Gadobutrol
  • Contrast-Induced Acute Kidney Injury in Radiologic Management of Acute Ischemic Stroke in the Emergency Setting
Show more Patient Safety

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire