Index by author
Nagaraj, S.
- EDITOR'S CHOICEAdult BrainYou have accessSpiral T1 Spin-Echo for Routine Postcontrast Brain MRI Exams: A Multicenter Multireader Clinical EvaluationM.B. Ooi, Z. Li, R.K. Robison, D. Wang, A.G. Anderson, N.R. Zwart, A. Bakhru, S. Nagaraj, T. Mathews, S. Hey, J.J. Koonen, I.E. Dimitrov, H.T. Friel, Q. Lu, M. Obara, I. Saha, H. Wang, Y. Wang, Y. Zhao, M. Temkit, H.H. Hu, T.L. Chenevert, O. Togao, J.A. Tkach, U.D. Nagaraj, M.C. Pinho, R.K. Gupta, J.E. Small, M.M. Kunst, J.P. Karis, J.B. Andre, J.H. Miller, N.K. Pinter and J.G. PipeAmerican Journal of Neuroradiology February 2020, 41 (2) 238-245; DOI: https://doi.org/10.3174/ajnr.A6409
The authors report a multicenter multireader study that was designed to compare spiral with standard-of-care Cartesian postcontrast structural brain MR imaging on the basis of relative performance in 10 metrics of image quality, artifact prevalence, and diagnostic benefit. Seven clinical sites acquired 88 total subjects. For each subject, sites acquired 2 postcontrast MR imaging scans: a spiral 2D T1 spin-echo, and 1 of 4 routine Cartesian 2D T1 spin-echo/TSE scans. Nine neuroradiologists independently reviewed each subject, with the matching pair of spiral and Cartesian scans compared side-by-side, and scored the subject on 10 image-quality metrics. Spiral was superior to Cartesian in 7 of 10 metrics (flow artifact mitigation, SNR, GM/WM contrast, image sharpness, lesion conspicuity, preference for diagnosing abnormal enhancement, and overall intracranial image quality), comparable in 1 of 10 metrics (motion artifacts), and inferior in 2 of 10 metrics (susceptibility artifacts, overall extracranial image quality). Spiral 2D T1 spin-echo for routine structural brain MR imaging is feasible in the clinic with conventional scanners and was preferred by neuroradiologists for overall postcontrast intracranial evaluation.
Nagaraj, U.D.
- EDITOR'S CHOICEAdult BrainYou have accessSpiral T1 Spin-Echo for Routine Postcontrast Brain MRI Exams: A Multicenter Multireader Clinical EvaluationM.B. Ooi, Z. Li, R.K. Robison, D. Wang, A.G. Anderson, N.R. Zwart, A. Bakhru, S. Nagaraj, T. Mathews, S. Hey, J.J. Koonen, I.E. Dimitrov, H.T. Friel, Q. Lu, M. Obara, I. Saha, H. Wang, Y. Wang, Y. Zhao, M. Temkit, H.H. Hu, T.L. Chenevert, O. Togao, J.A. Tkach, U.D. Nagaraj, M.C. Pinho, R.K. Gupta, J.E. Small, M.M. Kunst, J.P. Karis, J.B. Andre, J.H. Miller, N.K. Pinter and J.G. PipeAmerican Journal of Neuroradiology February 2020, 41 (2) 238-245; DOI: https://doi.org/10.3174/ajnr.A6409
The authors report a multicenter multireader study that was designed to compare spiral with standard-of-care Cartesian postcontrast structural brain MR imaging on the basis of relative performance in 10 metrics of image quality, artifact prevalence, and diagnostic benefit. Seven clinical sites acquired 88 total subjects. For each subject, sites acquired 2 postcontrast MR imaging scans: a spiral 2D T1 spin-echo, and 1 of 4 routine Cartesian 2D T1 spin-echo/TSE scans. Nine neuroradiologists independently reviewed each subject, with the matching pair of spiral and Cartesian scans compared side-by-side, and scored the subject on 10 image-quality metrics. Spiral was superior to Cartesian in 7 of 10 metrics (flow artifact mitigation, SNR, GM/WM contrast, image sharpness, lesion conspicuity, preference for diagnosing abnormal enhancement, and overall intracranial image quality), comparable in 1 of 10 metrics (motion artifacts), and inferior in 2 of 10 metrics (susceptibility artifacts, overall extracranial image quality). Spiral 2D T1 spin-echo for routine structural brain MR imaging is feasible in the clinic with conventional scanners and was preferred by neuroradiologists for overall postcontrast intracranial evaluation.
Nagata, H.
- Adult BrainYou have accessVisualization of Lenticulostriate Arteries on CT Angiography Using Ultra-High-Resolution CT Compared with Conventional-Detector CTK. Murayama, S. Suzuki, H. Nagata, J. Oda, I. Nakahara, K. Katada, K. Fujii and H. ToyamaAmerican Journal of Neuroradiology February 2020, 41 (2) 219-223; DOI: https://doi.org/10.3174/ajnr.A6377
Nagayama, Y.
- Adult BrainYou have accessMetal Artifact Reduction in Head CT Performed for Patients with Deep Brain Stimulation Devices: Effectiveness of a Single-Energy Metal Artifact Reduction AlgorithmY. Nagayama, S. Tanoue, S. Oda, D. Sakabe, T. Emoto, M. Kidoh, H. Uetani, A. Sasao, T. Nakaura, O. Ikeda, K. Yamada and Y. YamashitaAmerican Journal of Neuroradiology February 2020, 41 (2) 231-237; DOI: https://doi.org/10.3174/ajnr.A6375
Najm, M.
- Practice PerspectivesOpen AccessDisplaying Multiphase CT Angiography Using a Time-Variant Color Map: Practical Considerations and Potential Applications in Patients with Acute StrokeJ.M. Ospel, O. Volny, W. Qiu, M. Najm, N. Kashani, M. Goyal and B.K. MenonAmerican Journal of Neuroradiology February 2020, 41 (2) 200-205; DOI: https://doi.org/10.3174/ajnr.A6376
Nakahara, I.
- Adult BrainYou have accessVisualization of Lenticulostriate Arteries on CT Angiography Using Ultra-High-Resolution CT Compared with Conventional-Detector CTK. Murayama, S. Suzuki, H. Nagata, J. Oda, I. Nakahara, K. Katada, K. Fujii and H. ToyamaAmerican Journal of Neuroradiology February 2020, 41 (2) 219-223; DOI: https://doi.org/10.3174/ajnr.A6377
Nakaura, T.
- Adult BrainYou have accessMetal Artifact Reduction in Head CT Performed for Patients with Deep Brain Stimulation Devices: Effectiveness of a Single-Energy Metal Artifact Reduction AlgorithmY. Nagayama, S. Tanoue, S. Oda, D. Sakabe, T. Emoto, M. Kidoh, H. Uetani, A. Sasao, T. Nakaura, O. Ikeda, K. Yamada and Y. YamashitaAmerican Journal of Neuroradiology February 2020, 41 (2) 231-237; DOI: https://doi.org/10.3174/ajnr.A6375
Nietert, P.J.
- LETTERYou have accessReply:D.R. Roberts, D. Asemani, P.J. Nietert, M.A. Eckert, D.C. Inglesby, J.J. Bloomberg, M.S. George and T.R. BrownAmerican Journal of Neuroradiology February 2020, 41 (2) E8; DOI: https://doi.org/10.3174/ajnr.A6400