Index by author
Thomas, A.J.
- InterventionalYou have accessImplications of the Collar Sign in Incompletely Occluded Aneurysms after Pipeline Embolization Device Implantation: A Follow-Up StudyS. Gomez-Paz, Y. Akamatsu, J.M. Moore, C.S. Ogilvy, A.J. Thomas and C.J. GriessenauerAmerican Journal of Neuroradiology March 2020, 41 (3) 482-485; DOI: https://doi.org/10.3174/ajnr.A6415
Tintore, M.
- Adult BrainOpen AccessRatio of T1-Weighted to T2-Weighted Signal Intensity as a Measure of Tissue Integrity: Comparison with Magnetization Transfer Ratio in Patients with Multiple SclerosisD. Pareto, A. Garcia-Vidal, M. Alberich, C. Auger, X. Montalban, M. Tintoré, J. Sastre-Garriga and À. RoviraAmerican Journal of Neuroradiology March 2020, 41 (3) 461-463; DOI: https://doi.org/10.3174/ajnr.A6481
Tsankova, N.M.
- Adult BrainYou have accessVessel Wall MRI Enhancement in Noninflammatory Cerebral Amyloid AngiopathyQ. Hao, N.M. Tsankova, H. Shoirah, C.P. Kellner and K. NaelAmerican Journal of Neuroradiology March 2020, 41 (3) 446-448; DOI: https://doi.org/10.3174/ajnr.A6445
Tse, I.O.L.
- EDITOR'S CHOICEHead & NeckOpen AccessEarly Detection of Cancer: Evaluation of MR Imaging Grading Systems in Patients with Suspected Nasopharyngeal CarcinomaA.D. King, J.K.S. Woo, Q.-Y. Ai, F.K.F. Mo, T.Y. So, W.K.J. Lam, I.O.L. Tse, A.C. Vlantis, K.W.N. Yip, E.P. Hui, B.B.Y. Ma, R.W.K. Chiu, A.T.C. Chan, Y.M.D. Lo and K.C.A. ChanAmerican Journal of Neuroradiology March 2020, 41 (3) 515-521; DOI: https://doi.org/10.3174/ajnr.A6444
Dedicated nasopharyngeal MR imaging before (plain scan system) and after intravenous contrast administration (current and modified systems) was reviewed in patients from a nasopharyngeal carcinoma-endemic region, comprising 383 patients with suspected disease without nasopharyngeal carcinoma and 383 patients with nasopharyngeal carcinoma. The modified and plain scan systems refined primary tumor criteria, added a nodal assessment, and expanded the system from 4 to 5 grades. The current, modified, and plain scan MR imaging systems yielded sensitivities of 99.74%, 97.91%, and 97.65%, respectively, and specificities of 63.45%, 89.56%, and 86.42%, respectively. The modified system yielded significantly better performance than the current and plain systems. In conclusion, the authors propose a modified MR imaging grading system that improves diagnostic performance for nasopharyngeal carcinoma detection. Contrast was not valuable for low MR imaging grades, and the plain scan shows potential for use in screening programs.
Tsuboi, T.
- FunctionalYou have accessFunctional and Structural Connectivity Patterns Associated with Clinical Outcomes in Deep Brain Stimulation of the Globus Pallidus Internus for Generalized DystoniaL. Okromelidze, T. Tsuboi, R.S. Eisinger, M.R. Burns, M. Charbel, M. Rana, S.S. Grewal, C.-Q. Lu, L. Almeida, K.D. Foote, M.S. Okun and E.H. MiddlebrooksAmerican Journal of Neuroradiology March 2020, 41 (3) 508-514; DOI: https://doi.org/10.3174/ajnr.A6429