Table 3:

Evaluation indexes of T1WI, T2WI, FLAIR, and compound models in the training and testing sets

ModelsAUC (95% CI)AccuracySensitivitySpecificity
T1WI
 Training set0.781 (0.689–0.864)0.6900.7450.622
 Testing set0.500 (0.304–0.652)0.4590.5710.312
T2WI
 Training set0.959 (0.924–0.987)0.8570.8940.811
 Testing set0.833 (0.697–0.944)0.7840.8570.688
FLAIR
 Training set0.939 (0.898–0.979)0.8450.8510.838
 Testing set0.804 (0.664–0.918)0.7300.7620.688
Compound
 Training set0.989 (0.976–0.999)0.9400.9360.946
 Testing set0.905 (0.803–0.979)0.8380.9050.750