Table 2:

Logistic regression analysis showing the predictive factors of contrast-induced sialadenitis

VariablesUnivariateMultivariate
OR (95% CI)P ValueOR (95% CI)P Value
Age0.983 (0.956–1.012).249
Female sex2.798 (0.972–8.056).0574.420 (1.377–14.190).013
GFR0.992 (0.975–1.009).356
Volume of contrast administered1.008 (1.005–1.012)<.0011.007 (1.003–1.011)<.001
Guiding catheter tip located within ECA11.594 (5.026–26.747)<.0018.701 (3.459–21.885)<.001