TABLE 2:

Test-Retest and Interrater Reliability Versus Other Linear Measures of MTL Atrophy in 20 Patients with AD and 20 Control Subjects in the CT Group

Mean Difference Between MeasurementsIntraclass Correlation
Crude Values (mm) TestCrude (mm)Standardized (z)Coefficient
1st Rater, Test1st Rater, Retest2nd RaterWithin RaterBetween RatersWithin RaterBetween RatersWithin RaterBetween Raters
Mean radial width of the temporal horn ± SD
 Right4.6 ± 3.04.4 ± 2.94.5 ± 2.70.21 ± .67−0.20 ± 0.770.07 ± 0.22−0.09 ± 0.250.970.96
 Left4.0 ± 2.83.9 ± 2.74.1 ± 2.70.11 ± .48−0.19 ± 0.650.04 ± 0.17−0.05 ± 0.230.980.95
 Largest5.1 ± 3.04.9 ± 2.85.2 ± 3.00.25 ± .56−0.29 ± 0.810.09 ± 0.19−0.12 ± 0.260.980.94
Mean transverse widthof the temporal horn ± SD
 Right3.6 ± 1.53.7 ± 1.63.7 ± 1.5−0.09 ± .34−0.05 ± 0.59−0.06 ± 0.23−0.03 ± 0.410.970.93
 Left4.7 ± 2.54.8 ± 2.54.8 ± 2.3−0.14 ± .46−0.16 ± 0.58−0.05 ± 0.18−0.06 ± 0.230.980.97
 Largest5.1 ± 2.45.2 ± 2.25.3 ± 2.3−0.09 ± .42−0.18 ± 0.64−0.04 ± 0.18−0.08 ± 0.270.980.96
Mean minimum thickness of the MLT ± SD
 Right13.5 ± 3.314.2 ± 3.014.0 ± 4.1−0.71 ± 2.36−0.51 ± 2.47−0.22 ± 0.72−0.16 ± 0.760.710.73
 Left14.1 ± 3.414.3 ± 2.714.4 ± 3.9−0.20 ± 2.43−0.36 ± 2.68−0.06 ± 0.71−0.10 ± 0.780.690.66
 Smallest12.9 ± 3.313.4 ± 2.713.3 ± 4.1−0.43 ± 2.20−0.39 ± 2.42−0.13 ± 0.67−0.12 ± 0.730.740.78
  • Note.—Standardized (z) differences are computed by considering control subjects as the reference group.