TABLE 2:

Clinical characteristics of patients with acute ischemic stroke for whom angiography showed reocclusion after initial recanalization

Patient No.Age (yr)/SexInitial NIHSS ScoreSite and Initial Grade* of OcclusionACT (s)Treatment before ReocclusionTreatment for ReocclusionFinal Gradeb of OcclusionOutcomed
176/M26MCA, 3A269Reteplase (3 U), snare (n = 1)Reteplase (1U), snare (n = 1), angioplasty (n = 1)2Death
284/M18MCA, 3A252Reteplase (3 U)Reteplase (1 U)1Death
387/M21MCA, 3B251Reteplase (2 U), snare (n = 1), angioplasty (n = 2)Reteplase (1 U), angioplasty (n = 1)2Death
468/M32ICA, 5255Reteplase (3 U), snare (n = 1)Angioplasty (n = 1), 2.5 × 12-mm S660 stent (n = 1)1Death
550/F26MCA, 3ANAReteplase (3 U), angioplasty (n = 1)Reteplase (1 U), angioplasty (n = 1)2Death
683/M14MCA, 3A250Reteplase (3 U), angioplasty (n = 1)Reteplase (2 U), snare (n = 1), 2.25 × 13-mm Bx VELOCITY stent (n = 1)3AmRS 4
773/M30BA, 4BNAReteplase (3 U), angioplasty (n = 1)Reteplase (1 U), snare (n = 1)4ADeath
875/F20ICA, 4A257Reteplase (2 U), snare (n = 1)Reteplase (2 U), snare (n = 1), angioplasty (n = 1)2mRS 5
  • Note.—NIHSS indicates National Institutes of Health Stroke Scale; ACT, activated coagulation time; M, male; F, female; MCA, middle cerebral artery; ICA, internal carotid artery; BA, basilar artery; NA, not available; mRS, modified Rankin scale.

  • * Grading system from Qureshi AI (7).

  • S660 stents were manufactured by Guidant, Temecula, CA; Bx VELOCITY stents were manufactured by Cordis, Miami Lakes, FL.

  • mRS scores were determined at follow-up 1 to 3 months after thrombolysis.