Reasons for nonrandomization into ISAT
Reason | No. (%) of Patients |
---|---|
Surgical clipping (n = 67) | |
Anatomy of aneurysm unsuitable, wide neck | 22 (33) |
Radiologist decision not suitable for embolization | 13 (19) |
Intracranial haematoma to be removed at the same time | 8 (12) |
Aneurysm size unsuitable | 6 (9) |
Unavailability of radiologist or angiography room | 6 (9) |
Anatomy, tortuous vessels | 5 (7) |
Patient requested surgery | 3 (4) |
Vessel could not be separated from aneurysm neck | 2 (3) |
Patient pregnant | 1 (1) |
Management not discussed with neuroradiologist on call | 1 (1) |
Endovascular coiling (n = 46) | |
Posterior circulation aneurysm | 18 (39) |
Patient requested endovascular therapy | 10 (22) |
Patient age or grade | 7 (15) |
Surgeon did not believe aneurysm was suitable for clipping | 5 (11) |
Anatomy unsuitable for surgery | 3 (6) |
Preexistent medical condition | 1 (2) |
Aneurysm partially treated | 1 (2) |
Outside referral after failed clipping | 1 (2) |