Filling of the wide-necked aneurysm
Aneurysm Filling (%) | Color of Silicone Injection | Aneurysmal Residue* Reference | Loop in the Parent Artery | ||||||
---|---|---|---|---|---|---|---|---|---|
Blue | Green | Red | Gray | Black | Pink | Violet | |||
Coils only | — | — | — | — | — | — | — | Residual aneurysm | Yes |
30 | Residual aneurysm | No | |||||||
40–50 | Residual aneurysm | Yes | |||||||
50–60 | Residual aneurysm | No | |||||||
60–70 | Residual aneurysm | No | |||||||
70–80 | Residual neck | No | |||||||
80–90 | Residual neck | No | |||||||
100 | Complete | No |
* According to modified Jean Raymond grading scale.