Table 3:

Preprocedure angiographic findings and devices used for CRT

Patient No./Sex/Age (y)Occluded VesselRetrieval DevicesProximal Flow BlockadeAdditional TherapyDose of Urokinase
1/M/82ICA (C3)SoutenirMCPTCBA0
2/M/81ICA (C1)SoutenirMCPTCBA, LIF30*
3/M/91ICA (C7)SoutenirMCPTCBA0
4/F/78ICA (C6)No deviceMCNo0
5/M/88ICA (C6)In-TimeBGCPTCBA0
6/M/88ICA (C1)SoutenirBGCPTCBA0
7/F/87ICA (C3)In-TimeBGCNo0
8/M/78ICA (C7)SoutenirBGCNo0
9/M/64ICA (C1)No deviceBGCNo0
10/F/32ICA (C7)SoutenirBGCPTCBA0
11/M/73ICA (C7)No deviceBGCNo0
12/F/81ICA (C7)SoutenirBGCPTCBA0
13/F/69ICA (C7)SoutenirBGCPTCBA0
14/F/73ICA (C3)No deviceBGCNo9
  • Note:—CRT indicates clot removal therapy; ICA, internal carotid artery; C1, carotid segment; C3, lacerum segment; C6, ophthalmic segment; C7, terminal segment; MC, manual compression; BGC, balloon guide catheter; PTCBA, percutaneous transluminal cerebral balloon angioplasty; LIF, localized intra-arterial fibrinolysis.

  • * ×104 units.