Table 2:

Aneurysm detection with cerebral CTA according to aneurysm sizea

Aneurysm SizeResults (No.)Statistical Analysis (%)
TPTNFPFNSensitivitySpecificityPPVNPVAccuracy
<3 mm
    Group A24392875.0 (59.4–90.6)95.1 (87.8–100.0)92.3 (80.8–100.0)83.0 (72.3–93.6)86.3 (78.1–93.2)
    Group B17422481.0 (61.9–95.2)95.5 (88.6–100.0)89.5 (73.7–100.0)91.3 (82.6–97.8)90.8 (83.1–96.9)
3–8 mm
    Group A44391295.7 (89.1–100.0)97.5 (92.5–100.0)97.8 (93.3–100.0)95.1 (87.8–100.0)96.5 (93.0–100.0)
    Group B384210100 (100.0–100.0)97.7 (93.0–100.0)97.4 (92.3–100.0)100 (100.0–100.0)98.8 (96.3–100.0)
>8 mm
    Group A93900100 (100.0–100.0)100 (100.0–100.0)100 (100.0–100.0)100 (100.0–100.0)100 (100.0–100.0)
    Group B114200100 (100.0–100.0)100 (100.0–100.0)100 (100.0–100.0)100 (100.0–100.0)100 (100.0–100.0)
  • Note:—TP indicates true positive; TN, true negative; FP, false positive; FN, false negative.

  • a The data in parentheses are 95% confidence intervals.