Table 1:

Scanning parameters (3T)

Pre- and Postcontrast T1 FSEPre- and Postcontrast 3D-FLAIR3D T2-SSFPDelayed Postcontrast 3D-FLAIR
PlaneAxialAxialAxialAxial
TR (ms)500600015007600
TE (ms)10350194345
TI (ms)/2350/2100
Fat saturationSPIRSPIR/SPAIR
TSE factor318240100
Flip angle90°90°90°90°
Slice thickness (mm)1.510.60.6
Slices (no.)15302240
FOV (mm2)180 × 160230 × 190140 × 140200 × 255
Matrix256 × 205232 × 229264 × 248250 × 252
Parallel imagingNoYesNoYes
Averages4614
Scan time2 min 51 sec10 min 6 sec6 min 35 sec9 min 15 sec
  • Note:—SSFP indicates steady-state free precession; SPIR, spectral presaturation with inversion recovery; SPAIR, spectral attenuated inversion recovery; 3D FLAIR, Three dimensionally Fluid Attenuated Inversion Recovery; FSE, Fast spin echo; TR, time of repetition; TE, time of echo; TI, time of inversion; TSE, Turbo Spin-Echo; FOV, field of view; /, specific parameter is not available.