Table 3:

Diagnostic performance of 6 blinded readers in detection of MTS-related hippocampal signal alteration before and after image processing with a proprietary algorithm

ReaderSensitivitySpecificityPPVNPVAccuracy
Before processing
    R172.5598.0497.3778.130.85
    R260.7898.0496.8871.430.79
    R343.14100.00100.0063.750.72
    R458.8292.1688.2469.120.75
    R586.2780.3981.4885.420.83
    R666.67100.00100.0075.000.83
    Mean (SD)64.71 (14.46)94.77 (7.61)93.99 (7.50)73.81 (7.53)0.80 (0.05)
After Processing
    R174.5196.0895.0079.030.85
    R278.4398.0497.5681.970.88
    R372.5598.0497.3778.130.85
    R478.4392.1690.9181.030.85
    R572.5598.0497.3778.130.85
    R674.5198.0497.4479.370.86
    Mean (SD)75.16 (2.68)96.73 (2.37)95.94 (2.65)79.61 (1.57)0.86 (0.01)
  • Note:—R1 and R2 indicate radiology residents; R3 and R4, neuroradiology fellows; R5 and R6, attending neuroradiologists; PPV, positive predictive value; NPV, negative predictive value.