Acquisition parameters of EPIMix and routine protocols

Imaging ParameterEPIMix MR ImagingRoutine Brain MR Imaging
T1-FLAIRT2WIT2-FLAIRDWIT2*WIT1-FLAIRT2WIT2-FLAIRDWISWAN
FOV (cm)24242424242222222222
Section thickness (mm)5555555551.2
TR (ms)13002447581824472542240051759000541732.8
TI (ms)570.227518502465
TE (ms)19.310911510930.525.8119.4102.773.122.9
ETL (ms)5263213
Frequency matrix180180180180180360512288128288
Phase matrix180180180180180280512288192260
Flip angle90°90°90°90°90°90°90°90°90°15°
Bandwidth (kHz)250250250250250505041.6725041.67
Parallel imaging acceleration factorARC 3ARC 3ASSET 2.5ASSET 2.5
Net scan time (min:sec)1:121:582:292:251:192:33
Total scan time (min:sec)1:281:582:562:491:372:39
  • Note:—ARC indicates autocalibrating reconstruction for Cartesian imaging; ASSET, array spatial sensitivity encoding technique; ETL, echo-train length.