Table 4:

Interrater reliability and agreement regarding graduation and treatment decisions of vasospasm on CT

Interrater Reliability and Agreementa
All Raters (n = 3)Senior (n = 2)
Agreement (%)Interrater Reliability κ (95% CI)Agreement (%)Interrater Reliability κ (95% CI)
First rating (CTA)
 Detection of severe vasospasm in any arterial segment (>50% narrowing)630.27 (0.11–0.42)610.28 (0.10–0.46)
 Endovascular treatment?620.23 (0.06–0.39)610.23 (−0.01–0.46)
Second rating (CTA + CTP)
 Detection of severe vasospasm in any arterial segment (>50% narrowing)650.31 (0.15–0.46)730.46 (0.26–0.66)
 Endovascular treatment?750.47 (0.30–0.64)890.73 (0.55–0.91)
 Perfusion deficit?920.77 (0.63–0.91)930.82 (0.66–0.97)
  • a Interrater reliability was calculated using the Fleiss κ for all raters and Cohen κ for senior raters.