Clinical characteristics and follow-up results of 15 patients with an incomplete stent apposition at the stent edge
Patient No./Age (y)/Sex | R/L | Location of Lesion | Follow-up DSA (mo) | Rate of Stenosis (%) | Stent | Stent-induced Kinking |
---|---|---|---|---|---|---|
1/73/M | R | Proximal | 4 | 80 | Wallstent | + |
2/58/M | R | Proximal | 25 | 90 | Wallstent | |
3/77/M | L | Proximal | 4 | 60 | Wallstent | + |
4/61/M | R | Proximal | 18 | 84 | Wallstent | + |
5/77/M | L | Proximal | 7 | 70 | SMART | |
6/72/M | L | Proximal | 7 | 75 | SMART | + |
7/78/M | R | Proximal | 13 | 70 | SMART | |
8/69/M | L | Distal | 2 | 90 | Wallstent | |
9/60/M | L | Distal | 5 | 74 | Wallstent | + |
10/81/M | R | Distal | 4 | 90 | Wallstent | + |
11/80/M | L | Distal | 5 | 68 | Wallstent | |
12/81/M | R | Distal | 4 | 60 | Wallstent | |
13/73/F | R | Distal | 6 | 70 | Wallstent | + |
14/76/F | R | Distal | 3 | 95 | Wallstent | + |
15/66/M | R | Distal | 28 | 70 | Wallstent |
Note:—R indicates right; L, left; DSA, digital subtraction angiography.