Clinical NST for trigeminal neuropathya
Level A: Spatiotemporal Sensory Perception Direction Sensitivity <90% Static 2-Point Discrimination <18 mm | Level B: Contact Detection with Monofilament <2.83 | Level C: Pain Threshold and Tolerance Heat Temperature Threshold <47 Heat Temperature Tolerance <50 Pressure Pain Threshold <1.5 lb. Pressure Pain Tolerance <2.0 lb. | |
---|---|---|---|
Normal | Present | Present | Present |
Mild | Failed | Present | Present |
Moderate | Failed | Failed | Present |
Severe | Failed | Failed | Elevated |
Complete | Failed | Failed | Absent |
↵a Present: values recorded at test and control sites exhibit comparable sensitivity within published normative range. Failed: values recorded at test site sensitivity are less than that of control sites or published normative range. Elevated: values recorded at test site sensitivity are greater than that of control sites or published normative range but below maximum of test device (ie, 6 lbs.). Absent: values recorded at test site sensitivity are greater that maximum of test device (ie, 6 lbs.).