Table 1:

Clinical NST for trigeminal neuropathya

Level A: Spatiotemporal Sensory Perception Direction Sensitivity <90% Static 2-Point Discrimination <18 mmLevel B: Contact Detection with Monofilament <2.83Level C: Pain Threshold and Tolerance Heat Temperature Threshold <47 Heat Temperature Tolerance <50 Pressure Pain Threshold <1.5 lb. Pressure Pain Tolerance <2.0 lb.
NormalPresentPresentPresent
MildFailedPresentPresent
ModerateFailedFailedPresent
SevereFailedFailedElevated
CompleteFailedFailedAbsent
  • a Present: values recorded at test and control sites exhibit comparable sensitivity within published normative range. Failed: values recorded at test site sensitivity are less than that of control sites or published normative range. Elevated: values recorded at test site sensitivity are greater than that of control sites or published normative range but below maximum of test device (ie, 6 lbs.). Absent: values recorded at test site sensitivity are greater that maximum of test device (ie, 6 lbs.).