Patients with MS stenosis

No.Type of PTSideDisabilityaIpsilateral LSSinus StentedTreatment Efficiency
1VenousRight8StenosisLS then MSYes (after the MS stent placement)
2VenousRight9bNormalMSYes
3VenousLeft9StenosisLS+MSYes
4VenousRight8StenosisLS+MSYes
5VenousLeft3NormalNone
6VenousRight4HypoplasticNone
7VenousLeft5HypoplasticNone
8VenousRight9HypoplasticNone
  • a Disability was evaluated on a VAS from 0 (no tinnitus) to 10 (unbearable and extreme tinnitus).

  • b Patient 2 also had IIH, which also resolved after the stent placement.