Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • AJNR Case Collection
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • Special Collections
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
    • 2024 AJNR Journal Awards
    • Most Impactful AJNR Articles
  • Multimedia
    • AJNR Podcast
    • AJNR Scantastics
    • Video Articles
  • For Authors
    • Submit a Manuscript
    • Author Policies
    • Fast publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Manuscript Submission Guidelines
    • Imaging Protocol Submission
    • Submit a Case for the Case Collection
  • About Us
    • About AJNR
    • Editorial Board
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Other Publications
    • ajnr

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • AJNR Case Collection
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • Special Collections
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
    • 2024 AJNR Journal Awards
    • Most Impactful AJNR Articles
  • Multimedia
    • AJNR Podcast
    • AJNR Scantastics
    • Video Articles
  • For Authors
    • Submit a Manuscript
    • Author Policies
    • Fast publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Manuscript Submission Guidelines
    • Imaging Protocol Submission
    • Submit a Case for the Case Collection
  • About Us
    • About AJNR
    • Editorial Board
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

Welcome to the new AJNR, Updated Hall of Fame, and more. Read the full announcements.


AJNR is seeking candidates for the position of Associate Section Editor, AJNR Case Collection. Read the full announcement.

 

OtherINTERVENTIONAL

Intravenous 3D Digital Subtraction Angiography in the Diagnosis of Unruptured Intracranial Aneurysms

S. Toyota, K. Iwaisako, H. Takimoto and T. Yoshimine
American Journal of Neuroradiology January 2008, 29 (1) 107-109; DOI: https://doi.org/10.3174/ajnr.A0822
S. Toyota
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
K. Iwaisako
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
H. Takimoto
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
T. Yoshimine
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

Abstract

SUMMARY: Recent progress in digital subtraction angiography (DSA) devices makes it possible to perform rotational angiography with high resolution and high sensitivity. We tried intravenous (IV) 3D DSA in patients who had undergone MR angiography (MRA) suggestive of unruptured intracranial aneurysms. IV 3D DSA can be used as an alternative method for imaging unruptured intracranial aneurysms suggested on MRA.

Cerebral angiography is an essential technique in the diagnostic imaging and preoperative evaluation of cerebral aneurysm; however, it is invasive and carries a certain risk of complications.1 Intravenous (IV) digital subtraction angiography (DSA) has been used in some patients for the less invasive examination of cerebral, abdominal, and peripheral arteries.2,3 With the recent progress in DSA devices, it is possible to perform rotational angiography with high resolution and high sensitivity.4,5 We performed IV 3D DSA for the diagnosis of unruptured intracranial aneurysms.

Technique and Representative Cases

From August 2006 to December 2006, IV 3D DSA was performed in 29 outpatients (10 men, 19 women; mean age, 58.8 ± 12.4 years) who had undergone time-of-flight MR angiography (MRA) suggestive of unruptured intracranial aneurysms. With IV 3D DSA, intracranial aneurysms were recognized in 11 patients (internal carotid artery, 7 patients; anterior communicating artery, 1 patient; middle cerebral artery, 1 patient; basilar artery, 1 patient; vertebral artery, 1 patient), but not in 18 patients.

Description of the Technique of IV 3D DSA

IV 3D DSA was obtained with rotational angiographies performed on a C-Arm (Infinix Celeve VS; Toshiba, Tokyo, Japan). This covers a total angular range of 200°, with a first rotation of 40°/s to acquire the mask images, a second rotation to return to the starting position, and a third rotation of 40°/s to acquire the opacified images. The type of detector in this system was an image intensifier (RTP12303J-G9E; Toshiba).

An 18-gauge angiocatheter was inserted into the right antecubital vein and linked with a connective tube for power injection. First, 15 mL of nonionic contrast medium (Omnipaque 350; Daiichi Seiyaku, Tokyo, Japan) was injected with a pump at a rate of 9 mL/s. The delay time from the start of contrast injection to the time when the common carotid arteries were filled with contrast was measured with DSA. Then 50 mL of the contrast medium was injected at a rate of 9 mL/s. The acquisition of source images was started after the start of contrast injection. The acquisition matrix was 512 × 512.

This protocol resulted in a rotational series of 200 subtracted images. Rotational angiography data were automatically transferred to a personal computer (XIDF-100A; Toshiba), which reconstructed 3D volume data. The matrix of transferred data were transformed from 512 × 512 to 256 × 256 by voxel addition. The 3D volume data were transferred to a commercially available multimodality 3D workstation (ZIO M900TXA; ZIO Software, Tokyo, Japan), processed, and presented. Available visualization of algorithms included maximum intensity projection (MIP) and volume rendering.

Representative Cases

Case 1: A 72-year-old woman.

MRA was suggestive of an aneurysm in the right internal carotid artery (Fig 1A). With volume rendering images of IV 3D DSA, the aneurysm and its relationship with the surrounding arterial branches were depicted (Fig 1B). The size of the aneurysm could be measured with MIP (Fig 1C). She underwent additional intra-arterial (IA) 3D DSA due to a proposal of surgical treatment. IA 3D DSA was performed with the injection of 15 mL of nonionic contrast medium (Iopamiron 300; Nihon Schering, Osaka, Japan) into the right common carotid artery at a rate of 3 mL/s. With volume rendering images of IA 3D DSA, the aneurysm was depicted in higher spatial resolution, and small vessels surrounding the aneurysm were revealed (Fig 1D).

Fig 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 1.

MRA time-of-flight image (case 1). A, An aneurysm in the right internal carotid artery was suggested. B, Volume rendering image of IV 3D DSA (case 1). The aneurysm and its relationship with the surrounding arterial branches were depicted. 1 indicates internal carotid artery; 2, middle cerebral artery; 3, posterior cerebral artery; 4, A1 segment of the anterior cerebral artery. C, MIP of IV 3D DSA (case 1). The size of the aneurysm was 14.7 × 9.1 mm for the aneurysm sack and 5.5 mm for the neck. D, Volume rendering images of IA 3D DSA (case 1). The aneurysm was depicted in higher spatial resolution, and small vessels surrounding the aneurysm were revealed (arrows).

Case 2: A 73-year-old man.

MRA was suggestive of a small aneurysm in the anterior communicating artery (Fig 2A). With volume rendering images of IV 3D DSA, a small aneurysm was recognized and the surrounding arterial branches were depicted (Fig 2B). The aneurysm measured with MIP (Fig 2C) was so small that additional IA DSA was not performed.

Fig 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 2.

MRA time-of-flight image (case 2). A, A small aneurysm in the anterior communicating artery was suggested. B, Volume rendering images of IV 3D DSA (case 2). A small aneurysm was recognized, and the surrounding arterial branches were depicted. C, MIP of IV 3D DSA (case 2). The size of the aneurysm was 3.2 × 2.2 mm for the aneurysm sack and 3.2 mm for the neck.

Case 3: A 67-year-old woman.

MRA was suggestive of a small aneurysm in the left middle cerebral artery (Fig 3A), but it was not recognized with volume rendering images or MIP of IV 3D DSA (Fig 3B, -C). The suggested lesion was thought to be the curved portion of the M1 segment of the left middle cerebral artery.

Fig 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 3.

MRA time-of-flight image (case 3). A, A small aneurysm in the left middle cerebral artery was suggested. B, Volume rendering images of IV 3D DSA (case 3). The suggested aneurysm was not recognized. The suggested lesion was thought to be the curved portion of the M1 segment of the left middle cerebral artery. C, MIP of IV 3D DSA (case 3). The suggested aneurysm was not recognized.

Case 4: A 45-year-old man.

MRA was suggestive of a small aneurysm in the anterior communicating artery (Fig 4A), but it was not recognized with volume rendering images or MIP of IV 3D DSA (Fig 4B, -C). The suggested lesion was thought to be the curved portion of the anterior communicating artery.

Fig 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 4.

MRA time-of-flight image (case 4). A, A small aneurysm in the anterior communicating artery was suggested. B, Volume rendering images of IV 3D DSA (case 4). The suggested aneurysm was not recognized. The suggested lesion was thought to be the curved portion of the anterior communicating artery. C, MIP of IV 3D DSA (case 4). The suggested aneurysm was not recognized.

Discussion

The major advantage of IV DSA is the ability to obtain arteriograms relatively noninvasively through an IV injection of contrast medium, hence reducing the risk and cost of standard arterial catheterization. IV DSA has been used in some cases for the less invasive examination of cerebral, abdominal, and peripheral arteries3; however, because these vessels are not adequately demonstrated in all cases, intra-arterial DSA is mainly being performed.2 Because of progress in high-speed rotation of the C-arm and the technique of high-speed acquisition of images, rotational angiography can be performed with a high resolution.4,5 The spatial resolution and sensitivity of 3D images of our system are excellent because it can obtain 200 projection images in 1 acquisition and because the image intensifier has a high conversion factor (40 {cd/m2}/{μ G y/s}) and high contrast ratio (30:1 at 10% area contrast). These developments in DSA devices make IV 3D DSA possible. By manipulation of the 3D DSA data, lesions suggested on MRA can be depicted precisely in various ways. Volume rendering images of IV 3D DSA were more effective in demonstrating the relationship between the aneurysm and the adjacent vessels than MIP imaging.6 For examination of the existence of small aneurysms and for analysis of the size of aneurysms and vessels, MIP produced from the original nonthreshold 3D data was feasible.6

When data were transferred to the personal computer for reconstruction, the matrix size was transformed from 512 × 512 to 256 × 256 by voxel addition. This procedure is necessary for better contrast resolution because the contrast medium is diluted by a much larger volume of blood in IV 3D DSA.2 Therefore, compared with IA 3D DSA, the spatial resolution of IV 3D DSA is inferior, especially in the demonstration of small vessels; however, we think that IV 3D DSA has enough quality, at least as “the second check” of unruptured intracranial aneurysms suggested on MRA, even though small perforators cannot be depicted precisely. In our series, only 3 patients needed to undergo IA 3D DSA additionally due to a proposal for surgical treatment. As information about surgical treatment, IV 3D DSA was not inferior to IA 3D DSA in all 3 patients.

In the field of neurosurgery, 3D CTA is the most available method for the IV evaluation of cerebrovascular lesions.7 Recent studies have suggested that 3D CTA is equal or superior to conventional angiography in characterizing aneurysms for surgical planning.8 Neurosurgeons can use 3D CTA more easily than IV 3D DSA because they are accustomed to using a helical CT scanner that can perform multipurposely.7 Despite some disadvantages, we think that IV 3D DSA may be more suitable for preoperative study of endovascular treatment than 3D CTA, because the question of whether a working view for endovascular treatment is reproduced on the C-arm can be checked with IV 3D DSA.6

IV 3D DSA can be performed more quickly and safely than conventional angiography, especially in outpatients, without the risk and cost of arterial catheterization. IV DSA is generally a very safe procedure with low morbidity,2 but there have been a few descriptions of the extravasation of contrast material during IV DSA because of its high rate of injection.9 This complication occurs in approximately 5.2%, with an infusion rate of 14 mL/s.10 In our series, the rate was adjusted to 9 mL/s, which was less than in Pinto et al10, and we did not experience extravasation of contrast material during IV 3D DSA, or other complications.

Conclusion

With the recent progress in DSA devices, we could perform IV 3D DSA less invasively in the field of neuroradiology. Despite some disadvantages, IV 3D DSA can be used as an alternative method for imaging unruptured intracranial aneurysms suspicious on MRA.

References

  1. ↵
    Grzyska U, Freitag J, Zeumer H. Selective cerebral intraarterial DSA: complication rate and control of risk factors. Neuroradiology 1990;32:296–99
    CrossRefPubMed
  2. ↵
    Butler P. Intravenous digital subtraction angiography. Br J Hosp Med 1986;35:30–36
    PubMed
  3. ↵
    Modic MT, Weinstein MA, Pavlicek W, et al. Intravenous digital subtraction angiography: peripheral versus central injection of contrast material. Radiology 1983;147:711–15
    PubMed
  4. ↵
    Tu RK, Cohen WA, Maravilla KR, et al. Digital subtraction rotational angiography for aneurysms of the intracranial anterior circulation: injection method and optimization. AJNR Am J Neuroradiol 1996;17:1127–36
    Abstract
  5. ↵
    Abe T, Hirohata M, Tanaka N, et al. Clinical benefits of rotational 3D angiography in endovascular treatment of ruptured cerebral aneurysm. AJNR Am J Neuroradiol 2002;23:686–88
    Abstract/FREE Full Text
  6. ↵
    Missler U, Hundt C, Wiesmann M, et al. Three-dimensional reconstructed rotational digital subtraction angiography in planning treatment of intracranial aneurysms. Eur Radiol 2000;10:564–68
    CrossRefPubMed
  7. ↵
    Tacke J, Klein HM, Bertalanffy H, et al. Clinical significance of three-dimensional helical CT in neurosurgery. Minim Invasive Neurosurg 1997;40:30–35
    PubMed
  8. ↵
    Korogi Y, Takahashi M, Katada K, et al. Intracranial aneurysms: detection with three-dimensional CT angiography with volume rendering—comparison with conventional angiographic and surgical findings. Radiology 1999;211:497–506
    PubMed
  9. ↵
    Ball JB Jr, Lukin RR, Tomsick TA, et al. Complications of intravenous digital subtraction angiography. Arch Neurol 1985;42:969–72
    CrossRefPubMed
  10. ↵
    Pinto RS, Manuell M, Kricheff II. Complications of digital intravenous angiography: experience in 2488 cervicocranial examinations. AJR Am J Roentgenol 1984;143:1295–99
    PubMed
  • Received April 14, 2007.
  • Accepted after revision June 22, 2007.
  • Copyright © American Society of Neuroradiology
View Abstract
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 29 (1)
American Journal of Neuroradiology
Vol. 29, Issue 1
January 2008
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Intravenous 3D Digital Subtraction Angiography in the Diagnosis of Unruptured Intracranial Aneurysms
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
S. Toyota, K. Iwaisako, H. Takimoto, T. Yoshimine
Intravenous 3D Digital Subtraction Angiography in the Diagnosis of Unruptured Intracranial Aneurysms
American Journal of Neuroradiology Jan 2008, 29 (1) 107-109; DOI: 10.3174/ajnr.A0822

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Intravenous 3D Digital Subtraction Angiography in the Diagnosis of Unruptured Intracranial Aneurysms
S. Toyota, K. Iwaisako, H. Takimoto, T. Yoshimine
American Journal of Neuroradiology Jan 2008, 29 (1) 107-109; DOI: 10.3174/ajnr.A0822
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • Technique and Representative Cases
    • Discussion
    • Conclusion
    • References
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Crossref (8)
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • Meta-analysis of diagnostic significance of sixty-four-row multi-section computed tomography angiography and three-dimensional digital subtraction angiography in patients with cerebral artery aneurysm
    Wei Guo, Xu-Ying He, Xi-Feng Li, Dong-Xiang Qian, Jian-Quan Yan, De-Lin Bu, Chuan-Zhi Duan
    Journal of the Neurological Sciences 2014 346 1-2
  • Time-resolved C-arm cone beam CT angiography (TR-CBCTA) imaging from a single short-scan C-arm cone beam CT acquisition with intra-arterial contrast injection
    Yinsheng Li, John W Garrett, Ke Li, Yijing Wu, Kevin Johnson, Sebastian Schafer, Charles Strother, Guang-Hong Chen
    Physics in Medicine & Biology 2018 63 7
  • Direct Percutaneous Carotid Artery Stenting for a Patient with Absence of the Common Carotid Artery
    S. Toyota, A. Wakayama, T. Yoshimine
    Interventional Neuroradiology 2012 18 3
  • SEPARATE DEMONSTRATION OF ARTERIAL- AND VENOUS-PHASE BY 3D-CT ANGIOGRAPHY FOR BRAIN TUMORS USING 64-MULTIDETECTOR ROW CT: 3D-CT ARTERIOGRAPHY AND 3D-CT VENOGRAPHY
    HIROMICHI KASUYA, MASATO MATSUMOTO, RYOJI MUNAKATA, HIROYUKI MURAMATSU, TSUYOSHI ICHIKAWA, TAKU SATO, YUJI ENDO, JUN SAKUMA, KYOUICHI SUZUKI, TATSUYA SASAKI, NAMIO KODAMA
    FUKUSHIMA JOURNAL OF MEDICAL SCIENCE 2009 55 1
  • IV Flat Detector CT Angiography in Flat Detector CT Image-Guided Minimally Invasive Surgery for the Treatment of Intracerebral Hypertensive Hemorrhage
    Zhang Shu, Wei Wang, Yufa Qiu, Lihong Zhang, Yu Zheng, Jian Wang, Wenyi Li, Jiajia Ge, Ying Yu, Nan Lv, Chi Wang
    American Journal of Neuroradiology 2024 45 5
  • Morphometric Analysis of parameters of Internal Carotid Artery—Potential Clinical Implications
    Suyashi Sharma, Shilpi G Dixit, Pushpinder S Khera, Ashish K Nayyar, Surajit Ghatak
    Neurology India 2021 69 6
  • Optimising image quality in intravenous cerebral cone beam computed tomography
    Lisa Broadley, Brendan Erskine, Elissa Marshall, Kyle Ewert, Bjoern Picker
    Journal of Medical Radiation Sciences 2024 71 1
  • Experimental study of MRI artifact from detachable coil for cerebral aneurysmal embolization
    Toshi ABE, Masaru HIROHATA, Yoshifumi SAITA, Yusuke UCHIYAMA, Norimitsu TANAKA, Yasuharu TAKEUCHI, Naofumi HAYABUCHI
    Journal of Neuroendovascular Therapy 2008 2 2

More in this TOC Section

  • SAVE vs. Solumbra Techniques for Thrombectomy
  • CT Perfusion&Reperfusion in Acute Ischemic Stroke
  • Delayed Reperfusion Post-Thrombectomy&Thrombolysis
Show more Interventional

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editors Choice
  • Fellow Journal Club
  • Letters to the Editor

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

Special Collections

  • Special Collections

Resources

  • News and Updates
  • Turn around Times
  • Submit a Manuscript
  • Author Policies
  • Manuscript Submission Guidelines
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Submit a Case
  • Become a Reviewer/Academy of Reviewers
  • Get Peer Review Credit from Publons

Multimedia

  • AJNR Podcast
  • AJNR SCANtastic
  • Video Articles

About Us

  • About AJNR
  • Editorial Board
  • Not an AJNR Subscriber? Join Now
  • Alerts
  • Feedback
  • Advertise with us
  • Librarian Resources
  • Permissions
  • Terms and Conditions

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire