Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • AJNR Case Collection
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • Special Collections
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
    • 2024 AJNR Journal Awards
    • Most Impactful AJNR Articles
  • Multimedia
    • AJNR Podcast
    • AJNR Scantastics
    • Video Articles
  • For Authors
    • Submit a Manuscript
    • Author Policies
    • Fast publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Manuscript Submission Guidelines
    • Imaging Protocol Submission
    • Submit a Case for the Case Collection
  • About Us
    • About AJNR
    • Editorial Board
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Other Publications
    • ajnr

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • AJNR Case Collection
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • Special Collections
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
    • 2024 AJNR Journal Awards
    • Most Impactful AJNR Articles
  • Multimedia
    • AJNR Podcast
    • AJNR Scantastics
    • Video Articles
  • For Authors
    • Submit a Manuscript
    • Author Policies
    • Fast publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Manuscript Submission Guidelines
    • Imaging Protocol Submission
    • Submit a Case for the Case Collection
  • About Us
    • About AJNR
    • Editorial Board
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

Welcome to the new AJNR, Updated Hall of Fame, and more. Read the full announcements.


AJNR is seeking candidates for the position of Associate Section Editor, AJNR Case Collection. Read the full announcement.

 

ReplyLetter

Reply

R. Aviv, T.Y. Lee and M. Sharma
American Journal of Neuroradiology April 2012, 33 (4) E62; DOI: https://doi.org/10.3174/ajnr.A3051
R. Aviv
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
T.Y. Lee
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M. Sharma
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

We thank Drs Pulli and Yoo for their interest in our results and their subsequent confirmation of our study findings.1 Our work highlighted the danger of extrapolating findings from previous-generation scanners to newer, faster scanners. In particular, before our publication, there was an established opinion that CTA-signal intensities (SIs) were CBV-weighted and could, in addition to providing vascular data, provide an estimate of infarct core. This observation was true for older-generation scanners and was likely due to the increased scanning time required to cover the region of interest. Slower scanning times allowed contrast to reach the blood vessels in the ischemic/infarct region associated with prolonged transit time.

With the advent of modern scanners, the observation is no longer true. The role of CTA, in our opinion, remains the delineation of vascular anatomy, including the site of occlusion and presence of collaterals. CTA protocols should be optimized for vascular, not parenchymal, imaging. Estimation of infarct volume on CTA-SI was useful when CTP was not widely available but should be relegated to the history books. CTP studies provide outstanding estimates of core and tissue at risk with the area under the curve associated with thresholded parameters approaching 0.90 for core determination.2 For those centers where CTP is unavailable, we have shown that a postcontrast CT (PCT) following CTA demonstrates hypoattenuation that closely estimates core. PCT can be obtained at a lower dose than CTP. We strongly favor CTP over a PCT approach and have previously shown that infarct can be more confidently and correctly diagnosed by using CTP than noncontrast CT or CTA source images.3

References

  1. 1.↵
    1. Sharma M,
    2. Fox AJ,
    3. Symons S,
    4. et al
    . CT angiographic source images: flow- or volume-weighted? AJNR Am J Neuroradiol 2011;32: 359–64
    Abstract/FREE Full Text
  2. 2.↵
    1. Bivard A,
    2. Spratt N,
    3. Levi C,
    4. et al
    . Perfusion computer tomography: imaging and clinical validation in acute ischaemic stroke. Brain 2011;134: 3408–16
    Abstract/FREE Full Text
  3. 3.↵
    1. Hopyan J,
    2. Ciarallo A,
    3. Dowlatshahi D,
    4. et al
    . Certainty of stroke diagnosis: incremental benefit with CT perfusion over noncontrast CT and CT angiography. Radiology 2010;255: 142–53
    CrossRefPubMed
  • © 2012 by American Journal of Neuroradiology
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 33 (4)
American Journal of Neuroradiology
Vol. 33, Issue 4
1 Apr 2012
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Reply
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
R. Aviv, T.Y. Lee, M. Sharma
Reply
American Journal of Neuroradiology Apr 2012, 33 (4) E62; DOI: 10.3174/ajnr.A3051

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Reply
R. Aviv, T.Y. Lee, M. Sharma
American Journal of Neuroradiology Apr 2012, 33 (4) E62; DOI: 10.3174/ajnr.A3051
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • References
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • CT Angiography Source Images with Modern Multisection CT Scanners: Delay Time from Contrast Injection to Imaging Determines Correlation with Infarct Core
  • Google Scholar

Cited By...

  • No citing articles found.
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • Reply:
  • Brain AVM’s Nidus: What if We Hadn’t Understood Anything?
  • Letter to the Editor regarding “Automated Volumetric Software in Dementia: Help or Hindrance to the Neuroradiologist?”
Show more Letters

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editors Choice
  • Fellow Journal Club
  • Letters to the Editor

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

Special Collections

  • Special Collections

Resources

  • News and Updates
  • Turn around Times
  • Submit a Manuscript
  • Author Policies
  • Manuscript Submission Guidelines
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Submit a Case
  • Become a Reviewer/Academy of Reviewers
  • Get Peer Review Credit from Publons

Multimedia

  • AJNR Podcast
  • AJNR SCANtastic
  • Video Articles

About Us

  • About AJNR
  • Editorial Board
  • Not an AJNR Subscriber? Join Now
  • Alerts
  • Feedback
  • Advertise with us
  • Librarian Resources
  • Permissions
  • Terms and Conditions

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire