Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

Research ArticleNeurointervention

Modifying Flow in the ICA Bifurcation: Pipeline Deployment from the Supraclinoid ICA Extending into the M1 Segment—Clinical and Anatomic Results

E. Nossek, D.J. Chalif, S. Chakraborty and A. Setton
American Journal of Neuroradiology November 2014, 35 (11) 2125-2129; DOI: https://doi.org/10.3174/ajnr.A4013
E. Nossek
aFrom the Department of Neurosurgery, Hofstra North Shore–Long Island Jewish School of Medicine and North Shore–Long Island Jewish Health System, Manhasset, New York.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
D.J. Chalif
aFrom the Department of Neurosurgery, Hofstra North Shore–Long Island Jewish School of Medicine and North Shore–Long Island Jewish Health System, Manhasset, New York.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
S. Chakraborty
aFrom the Department of Neurosurgery, Hofstra North Shore–Long Island Jewish School of Medicine and North Shore–Long Island Jewish Health System, Manhasset, New York.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
A. Setton
aFrom the Department of Neurosurgery, Hofstra North Shore–Long Island Jewish School of Medicine and North Shore–Long Island Jewish Health System, Manhasset, New York.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

References

  1. 1.↵
    1. Briganti F,
    2. Napoli M,
    3. Tortora F, et al
    . Italian multicenter experience with flow-diverter devices for intracranial unruptured aneurysm treatment with periprocedural complications–a retrospective data analysis. Neuroradiology 2012;54:1145–52
    CrossRefPubMedWeb of Science
  2. 2.↵
    1. Becske T,
    2. Kallmes DF,
    3. Saatci I, et al
    . Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial. Radiology 2013;267:858–68
    CrossRefPubMedWeb of Science
  3. 3.↵
    1. Saatci I,
    2. Yavuz K,
    3. Ozer C, et al
    . Treatment of intracranial aneurysms using the Pipeline flow-diverter embolization device: a single-center experience with long-term follow-up results. AJNR Am J Neuroradiol 2012;33:1436–46
    Abstract/FREE Full Text
  4. 4.↵
    1. Zanaty M,
    2. Chalouhi N,
    3. Tjoumakaris SI, et al
    . Flow diversion for complex middle cerebral artery aneurysms. Neuroradiology 2014;56:381–87
    CrossRefPubMedWeb of Science
  5. 5.↵
    1. Chalouhi N,
    2. Starke RM,
    3. Yang S, et al
    . Extending the indications of flow diversion to small, unruptured, saccular aneurysms of the anterior circulation. Stroke 2014;45:54–58
    Abstract/FREE Full Text
  6. 6.↵
    1. Yavuz K,
    2. Geyik S,
    3. Saatci I, et al
    . Endovascular treatment of middle cerebral artery aneurysms with flow modification with the use of the Pipeline embolization device. AJNR Am J Neuroradiol 2014;35:529–35
    Abstract/FREE Full Text
  7. 7.↵
    1. Wajnberg E,
    2. Silva TS,
    3. Johnson AK, et al
    . Progressive deconstruction: a novel aneurysm treatment using the Pipeline embolization device for competitive flow diversion: case report. Neurosurgery 2014; 10(suppl 1):E161–66
    CrossRefPubMed
  8. 8.↵
    1. Puffer RC,
    2. Kallmes DF,
    3. Cloft HJ, et al
    . Patency of the ophthalmic artery after flow diversion treatment of paraclinoid aneurysms. J Neurosurg 2012;116:892–96
    CrossRefPubMedWeb of Science
  9. 9.↵
    1. Darsaut TE,
    2. Bing F,
    3. Salazkin I, et al
    . Flow diverters can occlude aneurysms and preserve arterial branches: a new experimental model. AJNR Am J Neuroradiol 2012;33:2004–09
    Abstract/FREE Full Text
  10. 10.↵
    1. Kallmes DF,
    2. Ding YH,
    3. Dai D, et al
    . A new endoluminal, flow-disrupting device for treatment of saccular aneurysms. Stroke 2007;38:2346–52
    Abstract/FREE Full Text
  11. 11.↵
    1. Fiorella D,
    2. Woo HH,
    3. Albuquerque FC, et al
    . Definitive reconstruction of circumferential, fusiform intracranial aneurysms with the Pipeline embolization device. Neurosurgery 2008;62:1115–20; discussion 1120–21
    CrossRefPubMedWeb of Science
  12. 12.↵
    1. Shapiro M,
    2. Raz E,
    3. Becske T, et al
    . Variable porosity of the Pipeline embolization device in straight and curved vessels: a guide for optimal deployment strategy. AJNR Am J Neuroradiol 2014;35:727–33
    Abstract/FREE Full Text
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 35 (11)
American Journal of Neuroradiology
Vol. 35, Issue 11
1 Nov 2014
  • Table of Contents
  • Index by author
  • Complete Issue (PDF)
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Modifying Flow in the ICA Bifurcation: Pipeline Deployment from the Supraclinoid ICA Extending into the M1 Segment—Clinical and Anatomic Results
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
E. Nossek, D.J. Chalif, S. Chakraborty, A. Setton
Modifying Flow in the ICA Bifurcation: Pipeline Deployment from the Supraclinoid ICA Extending into the M1 Segment—Clinical and Anatomic Results
American Journal of Neuroradiology Nov 2014, 35 (11) 2125-2129; DOI: 10.3174/ajnr.A4013

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Modifying Flow in the ICA Bifurcation: Pipeline Deployment from the Supraclinoid ICA Extending into the M1 Segment—Clinical and Anatomic Results
E. Nossek, D.J. Chalif, S. Chakraborty, A. Setton
American Journal of Neuroradiology Nov 2014, 35 (11) 2125-2129; DOI: 10.3174/ajnr.A4013
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • ABBREVIATIONS:
    • Materials and Methods
    • Results
    • Discussion
    • Conclusions
    • References
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • PubMed
  • Google Scholar

Cited By...

  • Flow-Diversion Treatment for Unruptured ICA Bifurcation Aneurysms with Unfavorable Morphology for Coiling
  • Flow modification on the internal carotid artery bifurcation region and A1 segment after M1-internal carotid artery flow diverter deployment
  • Flow diversion beyond the circle of Willis: endovascular aneurysm treatment in peripheral cerebral arteries employing a novel low-profile flow diverting stent
  • Pipeline embolization device treatment of internal carotid artery terminus aneurysms
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • A Retrospective Study in Tentorial DAVFs
  • Proximal Protection Devices for Carotid Stenting
  • Guided vs Conventional Angiography Systems
Show more NEUROINTERVENTION

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire