Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • AJNR Case Collection
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • Special Collections
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
    • 2024 AJNR Journal Awards
    • Most Impactful AJNR Articles
  • Multimedia
    • AJNR Podcast
    • AJNR Scantastics
    • Video Articles
  • For Authors
    • Submit a Manuscript
    • Author Policies
    • Fast publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Manuscript Submission Guidelines
    • Imaging Protocol Submission
    • Submit a Case for the Case Collection
  • About Us
    • About AJNR
    • Editorial Board
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Other Publications
    • ajnr

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • AJNR Case Collection
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • Special Collections
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
    • 2024 AJNR Journal Awards
    • Most Impactful AJNR Articles
  • Multimedia
    • AJNR Podcast
    • AJNR Scantastics
    • Video Articles
  • For Authors
    • Submit a Manuscript
    • Author Policies
    • Fast publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Manuscript Submission Guidelines
    • Imaging Protocol Submission
    • Submit a Case for the Case Collection
  • About Us
    • About AJNR
    • Editorial Board
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

Welcome to the new AJNR, Updated Hall of Fame, and more. Read the full announcements.


AJNR is seeking candidates for the position of Associate Section Editor, AJNR Case Collection. Read the full announcement.

 

Research ArticleADULT BRAIN

Optimized, Minimal Specific Absorption Rate MRI for High-Resolution Imaging in Patients with Implanted Deep Brain Stimulation Electrodes

A.M. Franceschi, G.C. Wiggins, A.Y. Mogilner, T. Shepherd, S. Chung and Y.W. Lui
American Journal of Neuroradiology November 2016, 37 (11) 1996-2000; DOI: https://doi.org/10.3174/ajnr.A4865
A.M. Franceschi
aFrom the Departments of Radiology (A.M.F., G.C.W., T.S., S.C., Y.W.L.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for A.M. Franceschi
G.C. Wiggins
aFrom the Departments of Radiology (A.M.F., G.C.W., T.S., S.C., Y.W.L.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for G.C. Wiggins
A.Y. Mogilner
bNeurosurgery (A.Y.M.), New York University School of Medicine, New York, New York.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for A.Y. Mogilner
T. Shepherd
aFrom the Departments of Radiology (A.M.F., G.C.W., T.S., S.C., Y.W.L.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for T. Shepherd
S. Chung
aFrom the Departments of Radiology (A.M.F., G.C.W., T.S., S.C., Y.W.L.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for S. Chung
Y.W. Lui
aFrom the Departments of Radiology (A.M.F., G.C.W., T.S., S.C., Y.W.L.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Y.W. Lui
  • Article
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

References

  1. 1.↵
    1. Nutt JG,
    2. Anderson VC,
    3. Peacock JH, et al
    . DBS and diathermy interaction induces severe CNS damage. Neurology 2001;56:1384–86 doi:10.1212/WNL.56.10.1384 pmid:11376192
    Abstract/FREE Full Text
  2. 2.↵
    1. Henderson JM,
    2. Tkach J,
    3. Phillips M, et al
    . Permanent neurological deficit related to magnetic resonance imaging in a patient with implanted deep brain stimulation electrodes for Parkinson's disease: case report. Neurosurgery 2005;57:E1063; discussion E1063 doi:10.1227/01.NEU.0000180810.16964.3E pmid:16284543
    CrossRefPubMed
  3. 3.↵
    1. Larson PS,
    2. Richardson RM,
    3. Starr PA, et al
    . Magnetic resonance imaging of implanted deep brain stimulators: experience in a large series. Stereotact Funct Neurosurg 2008;86:92–100 pmid:18073522
    CrossRefPubMedWeb of Science
  4. 4.↵
    1. Sarkar SN,
    2. Papavassiliou E,
    3. Hackney DB, et al
    . Three-dimensional brain MRI for DBS patients within ultra-low radiofrequency power limits. Mov Disord 2014;29:546–49 doi:10.1002/mds.25808 pmid:24442797
    CrossRefPubMed
  5. 5.↵
    1. Chhabra V,
    2. Sung E,
    3. Mewes K, et al
    . Safety of magnetic resonance imaging of deep brain stimulator systems: a serial imaging and clinical retrospective study. J Neurosurg 2010;112:497–502 doi:10.3171/2009.7.JNS09572 pmid:19681685
    CrossRefPubMed
  6. 6.↵
    1. Fraix V,
    2. Chabardes S,
    3. Krainik A, et al
    . Effects of magnetic resonance imaging in patients with implanted deep brain stimulation systems. J Neurosurg 2010;113:1242–45 doi:10.3171/2010.1.JNS09951 pmid:20187699
    CrossRefPubMed
  7. 7.↵
    1. Tagliati M,
    2. Jankovic J,
    3. Pagan F, et al
    ; National Parkinson Foundation DBS Working Group. Safety of MRI in patients with implanted deep brain stimulation devices. Neuroimage 2009;47(suppl 2):T53–57 doi:10.1016/j.neuroimage.2009.04.044 pmid:19376247
    CrossRefPubMed
  8. 8.↵
    1. Rezai AR,
    2. Baker KB,
    3. Tkach JA, et al
    . Is magnetic resonance imaging safe for patients with neurostimulation systems used for deep brain stimulation? Neurosurgery 2005;57:1056–62; discussion 1056–62 doi:10.1227/01.NEU.0000186935.87971.2a pmid:16284576
    CrossRefPubMedWeb of Science
  9. 9.↵
    1. Spiegel J,
    2. Fuss G,
    3. Backens M, et al
    . Transient dystonia following magnetic resonance imaging in a patient with deep brain stimulation electrodes for the treatment of Parkinson disease: case report. J Neurosurg 2003;99:772–74 doi:10.3171/jns.2003.99.4.0772 pmid:14567615
    CrossRefPubMedWeb of Science
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 37 (11)
American Journal of Neuroradiology
Vol. 37, Issue 11
1 Nov 2016
  • Table of Contents
  • Index by author
  • Complete Issue (PDF)
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Optimized, Minimal Specific Absorption Rate MRI for High-Resolution Imaging in Patients with Implanted Deep Brain Stimulation Electrodes
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
A.M. Franceschi, G.C. Wiggins, A.Y. Mogilner, T. Shepherd, S. Chung, Y.W. Lui
Optimized, Minimal Specific Absorption Rate MRI for High-Resolution Imaging in Patients with Implanted Deep Brain Stimulation Electrodes
American Journal of Neuroradiology Nov 2016, 37 (11) 1996-2000; DOI: 10.3174/ajnr.A4865

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Optimized, Minimal Specific Absorption Rate MRI for High-Resolution Imaging in Patients with Implanted Deep Brain Stimulation Electrodes
A.M. Franceschi, G.C. Wiggins, A.Y. Mogilner, T. Shepherd, S. Chung, Y.W. Lui
American Journal of Neuroradiology Nov 2016, 37 (11) 1996-2000; DOI: 10.3174/ajnr.A4865
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • ABBREVIATIONS:
    • Materials and Methods
    • Results
    • Discussion
    • Conclusions
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Crossref (12)
  • Google Scholar

This article has been cited by the following articles in journals that are participating in Crossref Cited-by Linking.

  • A Comprehensive Practice Guideline for Magnetic Resonance Imaging Compatibility in Implanted Neuromodulation Devices
    Dawood Sayed, Krishnan Chakravarthy, Kasra Amirdelfan, Hemant Kalia, Kathleen Meacham, Prasad Shirvalkar, Steven Falowski, Erika Petersen, Jonathan M. Hagedorn, Jason Pope, John Leever, Timothy Deer
    Neuromodulation: Technology at the Neural Interface 2020 23 7
  • Effect of Device Configuration and Patient's Body Composition on the RF Heating and Nonsusceptibility Artifact of Deep Brain Stimulation Implants During MRI at 1.5T and 3T
    Bhumi Bhusal, Bach T. Nguyen, Pia P. Sanpitak, Jasmine Vu, Behzad Elahi, Joshua Rosenow, Mark J. Nolt, Roberto Lopez‐Rosado, Julie Pilitsis, Marisa DiMarzio, Laleh Golestanirad
    Journal of Magnetic Resonance Imaging 2021 53 2
  • Safety of Simultaneous Scalp or Intracranial EEG during MRI: A Review
    Hassan B. Hawsawi, David W. Carmichael, Louis Lemieux
    Frontiers in Physics 2017 5
  • Evaluation of a Workflow to Define Low Specific Absorption Rate MRI Protocols for Patients With Active Implantable Medical Devices
    Jessica A. Martinez, Kévin Moulin, Bryan Yoo, Yu Shi, Hyun J. Kim, Pablo J. Villablanca, Daniel B. Ennis
    Journal of Magnetic Resonance Imaging 2020 52 1
  • The role of neuromodulation in the management of drug-resistant epilepsy
    HusamEddin Salama, Ahmed Salama, Logan Oscher, George I. Jallo, Nir Shimony
    Neurological Sciences 2024 45 9
  • Preoperative Magnetic Resonance Image Quality in Motion Disorder Patients Scheduled for Deep Brain Stimulation Surgery
    Elsa M. Ronde, Marja Silvasti-Lundell, Johanna Pekkola, Minna Tallgren, Riku Kivisaari
    Stereotactic and Functional Neurosurgery 2020 98 6
  • MRI in patients with implanted active devices: how to combine safety and image quality using a limited transmission field?
    Laura Lunden, Stephan Wolff, Sönke Peters, Catharina Drews, Christine Gierloff, Ulf Jensen-Kondering, Patrick Langguth, Jawid Madjidyar, Tim-Christian Piesch, Olav Jansen
    European Radiology 2020 30 5
  • Regarding Off-Label Scanning of MR Conditional Devices
    M.S. Brown
    American Journal of Neuroradiology 2016 37 11
  • Safety of MRI in the localization of implanted intracranial electrodes for refractory epilepsy
    Milad Yazdani, Justin Reagan, Madison Kocher, Michael Antonucci, James Taylor, Jonathan Edwards, William Alexander Vandergrift, Maria Vittoria Spampinato
    Journal of Neuroimaging 2021 31 3
  • The restricted SAR protocol: A method to assess MRI coil prototypes in an unconditionally safe manner
    Natalia Dudysheva, Franck Mauconduit, Redha Abdeddaim, Paul‐François Gapais, Sajad Hosseinnezhadian, Marc Dubois, Alexis Amadon, Nicolas Boulant, Lucie Hertz‐Pannier, Alexandre Vignaud
    Magnetic Resonance in Medicine 2024 91 4

More in this TOC Section

  • Diagnostic Neuroradiology of Monoclonal Antibodies
  • ML for Glioma Molecular Subtype Prediction
  • Segmentation of Brain Metastases with BLAST
Show more Adult Brain

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editors Choice
  • Fellow Journal Club
  • Letters to the Editor

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

Special Collections

  • Special Collections

Resources

  • News and Updates
  • Turn around Times
  • Submit a Manuscript
  • Author Policies
  • Manuscript Submission Guidelines
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Submit a Case
  • Become a Reviewer/Academy of Reviewers
  • Get Peer Review Credit from Publons

Multimedia

  • AJNR Podcast
  • AJNR SCANtastic
  • Video Articles

About Us

  • About AJNR
  • Editorial Board
  • Not an AJNR Subscriber? Join Now
  • Alerts
  • Feedback
  • Advertise with us
  • Librarian Resources
  • Permissions
  • Terms and Conditions

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire