Article Figures & Data
Tables
- Table 1:
Baseline characteristics of patients with minor to mild stroke who received mechanical thrombectomy
Patients (n = 33) Age (yr) (mean) (SD) 68 (16) Male (%) 14 (42.4) Hypertension (%) 21 (63.6) Diabetes mellitus (%) 4 (12.1) Atrial fibrillation (%) 13 (39.4) Coronary artery disease (%) 7 (21.2) Congestive heart failure (%) 3 (9.1) Hypercholesterolemia (%) 8 (24.2) Previous stroke (%) 0 History of smoking (%) 8 (24.2) Prestroke mRS 0 (%) 28 (84.8) 1 (%) 2 (6.1) 2 (%) 1 (3) 3 (%) 2 (6.1) Initial NIHSS score (median) (IQR) 5 (4–7) CT n = 18 MR imaging n = 15 ASPECTSa (median) (IQR) CT 10 (9–10) MR imaging 8 (7–9)b Time from stroke onset to imaging (min) (median) (IQR) 175 (72–279) Intravenous tPA (%) 22 (66.7) Time from stroke onset to intravenous tPAc (min) (median) (IQR) 156 (94–238) Time from stroke onset to groin puncture (min) (median) (IQR) 320 (237–528) Occlusion site ICA (excluding carotid T) (%) 4 (12.1) Tandem occlusion (cervical ICA and carotid T/M1) 3 (9.1) Carotid T (%) 2 (6.1) M1 (%) 17 (51.5) M2 (%) 7 (21.2) Collateral status 0 (%) 0 1 (%) 2 (6.1) 2 (%) 7 (21.2) 3 (%) 24 (72.7) Thrombus length (mm) 12 (10–16) - Table 2:
List of types, manufacturers, and number of maneuvers for mechanical thrombectomy
Device Manufacturer Size No. of Patients Treateda Total No. of Maneuvers Capture MindFrameb 4.0 × 20 mm 2 2 Catch Mini Baltc 3 × 15 mm 1 2 ERIC MicroVentiond 4 × 24 mm 3 4 Revive Codman Neurovasculare 4.5 × 22 mm 6 17 Solitaire 2 Covidienb 4 × 20 mm 15 31 Solitaire 2 Covidien 6 × 30 mm 4 4 Trevo ProVue Strykerf 4 × 20 mm 1 2 Trevo ProVue Stryker 3 × 20 mm 1 1 SofiaPlus MicroVention 6F 4g 4 Adapt Stenth Boston Scientifici 9 × 32 mm 1 Carotid Wallstenth Boston Scientific 9 × 40 mm 5 Carotid Wallstenth Boston Scientific 7 × 30 mm 3 Enterprise Stenth Codman & Shurtleffe 4 × 37 mm 1 Solitaire 2h Covidien 6 × 30 mm 1