Research ArticleAdult Brain
Effects of MRI Protocol Parameters, Preload Injection Dose, Fractionation Strategies, and Leakage Correction Algorithms on the Fidelity of Dynamic-Susceptibility Contrast MRI Estimates of Relative Cerebral Blood Volume in Gliomas
K. Leu, J.L. Boxerman and B.M. Ellingson
American Journal of Neuroradiology March 2017, 38 (3) 478-484; DOI: https://doi.org/10.3174/ajnr.A5027
K. Leu
aFrom the University of California, Los Angeles Brain Tumor Imaging Laboratory (K.A.B.L., B.M.E.), Center for Computer Vision and Imaging Biomarkers
bDepartment of Bioengineering (K.A.B.L., B.M.E.), Henry Samueli School of Engineering and Applied Science
dDepartments of Radiological Sciences (A.B.L., B.M.E.)
J.L. Boxerman
fDepartment of Diagnostic Imaging (J.L.B.), Rhode Island Hospital and Alpert Medical School of Brown University, Providence, Rhode Island.
B.M. Ellingson
aFrom the University of California, Los Angeles Brain Tumor Imaging Laboratory (K.A.B.L., B.M.E.), Center for Computer Vision and Imaging Biomarkers
bDepartment of Bioengineering (K.A.B.L., B.M.E.), Henry Samueli School of Engineering and Applied Science
cUniversity of California, Los Angeles Neuro-Oncology Program (B.M.E.), University of California, Los Angeles, Los Angeles, California
dDepartments of Radiological Sciences (A.B.L., B.M.E.)
eBiomedical Physics (B.M.E.), David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, California

Submit a Response to This Article
Jump to comment:
No eLetters have been published for this article.
In this issue
American Journal of Neuroradiology
Vol. 38, Issue 3
1 Mar 2017
Advertisement
K. Leu, J.L. Boxerman, B.M. Ellingson
Effects of MRI Protocol Parameters, Preload Injection Dose, Fractionation Strategies, and Leakage Correction Algorithms on the Fidelity of Dynamic-Susceptibility Contrast MRI Estimates of Relative Cerebral Blood Volume in Gliomas
American Journal of Neuroradiology Mar 2017, 38 (3) 478-484; DOI: 10.3174/ajnr.A5027
Effects of MRI Protocol Parameters, Preload Injection Dose, Fractionation Strategies, and Leakage Correction Algorithms on the Fidelity of Dynamic-Susceptibility Contrast MRI Estimates of Relative Cerebral Blood Volume in Gliomas
K. Leu, J.L. Boxerman, B.M. Ellingson
American Journal of Neuroradiology Mar 2017, 38 (3) 478-484; DOI: 10.3174/ajnr.A5027
Jump to section
Related Articles
Cited By...
- "Synthetic" DSC Perfusion MRI with Adjustable Acquisition Parameters in Brain Tumors Using Dynamic Spin-and-Gradient-Echo Echoplanar Imaging
- Performance of Standardized Relative CBV for Quantifying Regional Histologic Tumor Burden in Recurrent High-Grade Glioma: Comparison against Normalized Relative CBV Using Image-Localized Stereotactic Biopsies
- Utility of Percentage Signal Recovery and Baseline Signal in DSC-MRI Optimized for Relative CBV Measurement for Differentiating Glioblastoma, Lymphoma, Metastasis, and Meningioma
- Moving Toward a Consensus DSC-MRI Protocol: Validation of a Low-Flip Angle Single-Dose Option as a Reference Standard for Brain Tumors
- Brain DSC MR Perfusion in Children: A Clinical Feasibility Study Using Different Technical Standards of Contrast Administration
- Multisite Concordance of DSC-MRI Analysis for Brain Tumors: Results of a National Cancer Institute Quantitative Imaging Network Collaborative Project
This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.
More in this TOC Section
Similar Articles
Advertisement