Research ArticleNeurointervention
Comparison of Pipeline Embolization Device Sizing Based on Conventional 2D Measurements and Virtual Simulation Using the Sim&Size Software: An Agreement Study
J.M. Ospel, G. Gascou, V. Costalat, L. Piergallini, K.A. Blackham and D.W. Zumofen
American Journal of Neuroradiology March 2019, 40 (3) 524-530; DOI: https://doi.org/10.3174/ajnr.A5973
J.M. Ospel
aFrom the Diagnostic and Interventional Neuroradiology Section (J.M.O., K.A.B., D.W.Z.), Department of Radiology and Nuclear Medicine
G. Gascou
cDepartment of Neuroradiology (G.G., V.C., L.P.), Hôpital Gui de Chauliac, Centre Hospitalier Universitaire de Montpellier, University of Montpellier, Montpellier, France
V. Costalat
cDepartment of Neuroradiology (G.G., V.C., L.P.), Hôpital Gui de Chauliac, Centre Hospitalier Universitaire de Montpellier, University of Montpellier, Montpellier, France
L. Piergallini
cDepartment of Neuroradiology (G.G., V.C., L.P.), Hôpital Gui de Chauliac, Centre Hospitalier Universitaire de Montpellier, University of Montpellier, Montpellier, France
dPostgraduation School of Radiodiagnostics (L.P.), Università degli Studi di Milano, Milan, Italy.
K.A. Blackham
aFrom the Diagnostic and Interventional Neuroradiology Section (J.M.O., K.A.B., D.W.Z.), Department of Radiology and Nuclear Medicine
D.W. Zumofen
aFrom the Diagnostic and Interventional Neuroradiology Section (J.M.O., K.A.B., D.W.Z.), Department of Radiology and Nuclear Medicine
bDepartment of Neurosurgery (D.W.Z.), University Hospital Basel, University of Basel, Basel, Switzerland

References
- 1.↵
- 2.↵
- Geremia G,
- Haklin M,
- Brennecke L
- 3.↵
- Fiorella D,
- Kelly ME,
- Albuquerque FC, et al
- 4.↵
- Fiorella D,
- Lylyk P,
- Szikora I, et al
- 5.↵
- Lylyk P,
- Miranda C,
- Ceratto R, et al
- 6.↵ADMINISTRATION U.S. FOOD AND DRUG. Premarket Approval (PMA). 2011; https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?ID=P100018. Accessed August 8, 2018.
- 7.↵
- 8.↵
- Dabus G,
- Grossberg JA,
- Cawley CM, et al
- 9.↵
- 10.↵
- Kulcsar Z,
- Wetzel SG,
- Augsburger L, et al
- 11.↵
- Phillips TJ,
- Wenderoth JD,
- Phatouros CC, et al
- 12.↵
- 13.↵
- 14.↵
- Shapiro M,
- Raz E,
- Becske T, et al
- 15.↵
- Shapiro M,
- Raz E,
- Becske T, et al
- 16.↵
- Brinjikji W,
- Murad MH,
- Lanzino G, et al
- 17.↵Sim&Cure RdlV, 34790 Grabels, France. https://sim-and-cure.com/product. Accessed August, 29, 2018.
- 18.↵
- Kulcsár Z,
- Ernemann U,
- Wetzel SG, et al
- 19.↵
- van Rooij WJ,
- Sluzewski M
- 20.↵
- 21.↵
- Raz E,
- Shapiro M,
- Becske T, et al
- 22.↵
- Makoyeva A,
- Bing F,
- Darsaut TE, et al
- 23.↵
- Mut F,
- Cebral JR
- 24.↵
- 25.↵
- Bernardini A,
- Larrabide I,
- Petrini L, et al
- 26.↵
- 27.↵
- 28.↵
- 29.↵
- Bouillot P,
- Brina O,
- Yilmaz H, et al
- 30.↵
- 31.↵
- 32.↵
- Martinez-Galdamez M,
- Holtmannspöetter M,
- Isokangas M, et al
- 33.↵
- Nelson PK,
- Lylyk P,
- Szikora I, et al
- 34.↵
- Becske T,
- Kallmes DF,
- Saatci I, et al
- 35.
- Shapiro M,
- Becske T,
- Riina HA, et al
In this issue
American Journal of Neuroradiology
Vol. 40, Issue 3
1 Mar 2019
Advertisement
J.M. Ospel, G. Gascou, V. Costalat, L. Piergallini, K.A. Blackham, D.W. Zumofen
Comparison of Pipeline Embolization Device Sizing Based on Conventional 2D Measurements and Virtual Simulation Using the Sim&Size Software: An Agreement Study
American Journal of Neuroradiology Mar 2019, 40 (3) 524-530; DOI: 10.3174/ajnr.A5973
0 Responses
Comparison of Pipeline Embolization Device Sizing Based on Conventional 2D Measurements and Virtual Simulation Using the Sim&Size Software: An Agreement Study
J.M. Ospel, G. Gascou, V. Costalat, L. Piergallini, K.A. Blackham, D.W. Zumofen
American Journal of Neuroradiology Mar 2019, 40 (3) 524-530; DOI: 10.3174/ajnr.A5973
Jump to section
Related Articles
Cited By...
- High variability in physician estimations of flow-diverting stent deployment versus PreSize Neurovascular software simulation: a comparison study
- Predicting flow diverter sizing using the AneuGuideTM software: a validation study
- Comparison of Woven EndoBridge device sizing with conventional measurements and virtual simulation using the Sim&Size software: a multicenter experience
- Current and future usefulness and potential of virtual simulation in improving outcomes and reducing complications in endovascular treatment of unruptured intracranial aneurysms
- Review of current intracranial aneurysm flow diversion technology and clinical use
- Virtual simulation with Sim&Size software for Pipeline Flex Embolization: evaluation of the technical and clinical impact
- A Multicenter Pilot Study on the Clinical Utility of Computational Modeling for Flow-Diverter Treatment Planning
- Pipeline Sizing Based on Computer Simulation
This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.
More in this TOC Section
Similar Articles
Advertisement