Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • AJNR Case Collection
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • Special Collections
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
    • 2024 AJNR Journal Awards
    • Most Impactful AJNR Articles
  • Multimedia
    • AJNR Podcast
    • AJNR Scantastics
    • Video Articles
  • For Authors
    • Submit a Manuscript
    • Author Policies
    • Fast publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Manuscript Submission Guidelines
    • Imaging Protocol Submission
    • Submit a Case for the Case Collection
  • About Us
    • About AJNR
    • Editorial Board
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Other Publications
    • ajnr

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • AJNR Case Collection
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • Special Collections
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
    • 2024 AJNR Journal Awards
    • Most Impactful AJNR Articles
  • Multimedia
    • AJNR Podcast
    • AJNR Scantastics
    • Video Articles
  • For Authors
    • Submit a Manuscript
    • Author Policies
    • Fast publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Manuscript Submission Guidelines
    • Imaging Protocol Submission
    • Submit a Case for the Case Collection
  • About Us
    • About AJNR
    • Editorial Board
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

Welcome to the new AJNR, Updated Hall of Fame, and more. Read the full announcements.


AJNR is seeking candidates for the position of Associate Section Editor, AJNR Case Collection. Read the full announcement.

 

Research ArticleNeurointervention

MR-Guided Focused Ultrasound Thalamotomy in the Setting of Aneurysm Clip

Henrik Odéen, Lubdha M Shah, Viola Rieke, Dennis L Parker and Shervin Rahimpour
American Journal of Neuroradiology March 2024, 45 (3) 302-304; DOI: https://doi.org/10.3174/ajnr.A8109
Henrik Odéen
aDepartment of Radiology and Imaging Sciences (H.O., L.M.S., V.R., D.L.P.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Henrik Odéen
Lubdha M Shah
aDepartment of Radiology and Imaging Sciences (H.O., L.M.S., V.R., D.L.P.)
bDepartment of Neurosurgery (L.M.S., S.R.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Lubdha M Shah
Viola Rieke
aDepartment of Radiology and Imaging Sciences (H.O., L.M.S., V.R., D.L.P.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Dennis L Parker
aDepartment of Radiology and Imaging Sciences (H.O., L.M.S., V.R., D.L.P.)
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Dennis L Parker
Shervin Rahimpour
bDepartment of Neurosurgery (L.M.S., S.R.)
cDepartment of Biomedical Engineering, University of Utah, Salt Lake City, Utah (S.R.).
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

SUMMARY:

We report on a 75-year-old woman with a history of right MCA aneurysm clipping and medically refractive right-hand tremor. We successfully performed focused ultrasound thalamotomy of the left ventral intermediate nucleus under MR imaging-guidance at 3T. A thorough pretreatment evaluation of MR thermometry was critical to ensure that adequate precision could be achieved at the intended target. The tremor showed a 75% decrease at 24 hours postprocedure and a 50% decrease at a 3-month follow-up. There were no immediate adverse events.

ABBREVIATIONS:

MRgFUS
MR-guided focused ultrasound
MRT
MR thermometry
VIM
ventral intermediate nucleus

MR-guided focused ultrasound (MRgFUS) is a stereotactic technique that is increasingly being used for essential tremor and Parkinson-related tremor, in which high-intensity focused ultrasound is used to heat and ablate the thalamic target via precise intraprocedural target localization and the real-time monitoring of thermal dynamics with MR imaging.1,2 Staged bilateral thalamotomy is a regulatory-approved procedure with a potential for adverse events, including ataxia, dysarthria, and dysphasia.3⇓-5 However, there is a paucity of literature for MRgFUS in the setting of an intracranial aneurysm clip, which can present challenges with magnetic field inhomogeneity that can render MR thermometry (MRT) unreliable. Here, we present a case of unilateral MRgFUS ventral intermediate nucleus (VIM) thalamotomy for medically refractory tremor in the setting of a contralateral MCA aneurysm clip on a 3T MR imaging scanner. It is shown that a pretreatment MRT study can both aid in evaluating patient-specific MRT performance and result in a safe and efficacious procedure.

Case

The patient is a 75-year-old, right-handed woman with a history of hypertension, seizure disorder, and aneurysmal subarachnoid hemorrhage treated by MCA clip (Yasargil FE784K, conditional B0 ≤ 3T) ligation. The patient presented for a medically refractory right-hand tremor that was diagnosed 10 years prior. The patient had a preprocedural diagnosis of poststroke parkinsonism. The tremor was characterized by a prominent resting and postural tremor (right upper extremity: Clinical Rating Scale for Tremor [CRST]-A 7 [rest 3, postural 3, kinetic 1], CRST-B 11, CRST-C 16). The symptoms, including imbalance, affected her activities of daily living. After discussing the results from the main randomized controlled trial of MRgFUS for essential tremor, including the expected 50% reduction in tremor6 as well as the risks, benefits, and alternatives, the patient agreed to proceed with MRgFUS of the left VIM.

Before referral to our institution, the patient had a head CT scan done, according to the specifications of the MRgFUS vendor (Insightec). The day before the procedure, diagnostic MR imaging was performed for the structural evaluation and assessment of the degree of susceptibility artifact from the aneurysm clip in the right Sylvian fissure (CT shown in Online Supplemental Data). All MR imaging scans were performed at 3T (Skyra, Siemens). The MR imaging revealed extensive encephalomalacia and gliosis in the right MCA territory from aneurysmal subarachnoid hemorrhage and associated ischemic injury.

On the day of the treatment, the standard MRT protocols were tested with the patient in a focused ultrasonography transducer (Exablate Neuro, Insightec) without the coupling water bath. Before shaving her head or placing the stereotactic frame, the patient’s head was stabilized with pads, and imaging was performed with the embedded 2-channel head coils (Insightec). To investigate the homogeneity of the magnetic field and its impact on the MRT in the region of the left VIM target, 30-second duration MRT scans were acquired (8 dynamics). Scans were acquired in 3 orthogonal orientations, and for each orientation, both phase-encoding directions were acquired. Scans were performed with vendor-supplied single-echo (TMAP) and multi-echo (MEMP) protocols, for a total of 12 scans (Figure 1). TMAP has a frequency encoding bandwidth of 45 Hz/pixel, whereas MEMP has a bandwidth of 250 Hz/pixel, and hence, less susceptibility to off-resonance effects. For the multi-echo protocol, the echoes were optimally combined by weighting the signal by (TEj*Mj), where TE is the echo time, M is the magnitude image, and j = 1:N for N echoes.7 To investigate the precision of the measurement as a function of the spatial location, the standard deviation through time was calculated over each 30-second scan, as shown in Figure 1.

FIG 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIG 1.

CT scan and precision of MRT scans. MRT precision is measured as the standard deviation through time. For all 3 orientations, both phase-encoding directions for both the single-echo and multi-echo MRT sequences are shown. The scans were performed in the Exablate transducer (without the coupling water bath) with a 2-channel radiofrequency receiver coil. The patient’s head was stabilized with pads, but no stereotactic frame was used. The scans were performed before the patient’s head was shaved.

Following the verification of adequate MRT precision in the target area, the patient’s head was shaved, secured in a stereotactic head frame, and placed in a cold bath of degassed water. The patient was placed and secured on the MR imaging scanner table within the Exablate Neuro System (Insightec). After turning off the transducer elements that were interacting with the aneurysm clip, calcifications, etc, 861 of 1024 elements were active (Online Supplemental Data), with a skull attenuation ratio of 0.60. Next, test doses of ultrasonography were delivered while monitoring side effects and tremor reduction (Online Supplemental Data). No side effects were observed during the alignment sonications. During the verification sonications, substantial tremor reduction was not observed in the initially targeted location. Therefore, the target was moved 1 mm posterior and, later, 1.5 mm lateral, given that the patient did not have any sensory changes. The target was moved a total of 4 times, until a tremor reduction was seen with sonications at a temperature of ∼49–52°C. A total of 11 sonications with power ranging from 200–952 W, lasting between 11.5–31.4 seconds, and delivering between 2002–22202 J, were performed. The last 3 sonications were stopped prematurely by the patient because of discomfort, but it was not believed to be related to the aneurysm clip. MRT was successfully acquired during all sonications (Figure 2 and Online Supplemental Data), with a maximum temperature rise of 53.0°C (Online Supplemental Data).

FIG 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIG 2.

MRT of the hottest time point for one heating in each orientation (sonications 2, 7, and 11, respectively, are shown). The inlay in each panel zooms in on a 33 × 33-mm region around the focal spot.

Posttreatment T2-weighted images (axial sampling perfection with application-optimized contrasts by using different flip angle evolution [SPACE sequence; Siemens]) that were acquired immediately posttreatment in 20-channel head coil (Siemens) showed a hyperintense signal at the treatment site (Online Supplemental Data).

DISCUSSION

Patient-specific factors complicate the MRgFUS treatment of drug refractory tremor. Understanding the technical basis through additional pretreatment scans can aid in the safe performance of the procedure. Successful MRgFUS VIM ablation was achieved with a 75% tremor reduction recorded at 24 hours postprocedure in a patient with an MCA aneurysm clip. A pretreatment MRT study was performed to ensure that satisfactory temperature map quality could be achieved at the intended target. MRT was subsequently successfully acquired in all 3 orthogonal scan planes during the treatment. The pretreatment investigation helped guide which MRT sequence, scan planes, and phase-encoding direction would ultimately be most successful during the treatment. As shown in Figure 1, multi-echo protocols (MEMP), in general, provided better precision than did the single-echo protocol (TMAP) and were therefore used throughout the treatment. The additional preprocedure experiments showed that MRT would be feasible in the thalamus contralateral to the clip, and it was also predicted that MRT would be unreliable in the ipsilateral thalamus. Based on this experience, a pretreatment scan using the treatment hardware and pulse sequences (especially thermometry) is recommended to evaluate the extent of artifact, based on patient-specific clip type and location.

CONCLUSIONS

This report demonstrates the feasibility of MRgFUS thalamotomy in a patient with an aneurysm clip. We showed accurate MRT on a 3T scanner by using the multi-echo MRT sequence.

Footnotes

  • Grant Support: NIH grants R01EB028316 and R21EB033117.

  • Disclosure forms provided by the authors are available with the full text and PDF of this article at www.ajnr.org.

References

  1. 1.↵
    1. Jolesz FA,
    2. McDannold N
    . Current status and future potential of MRI-guided focused ultrasound surgery. J Magn Reson Imaging 2008;27:391–99 doi:10.1002/jmri.21261 pmid:18219674
    CrossRefPubMed
  2. 2.↵
    1. Moonen CT,
    2. Quesson B,
    3. Salomir R, et al
    . Thermal therapies in interventional MR imaging. Focused ultrasound. Neuroimaging Clin N Am 2001;11:737–47 pmid:11995428
    PubMed
  3. 3.↵
    1. Sinai A,
    2. Nassar M,
    3. Eran A, et al
    . Magnetic resonance-guided focused ultrasound thalamotomy for essential tremor: a 5-year single-center experience. J Neurosurg 2019;1–8 doi:10.1155/2018/9764807 pmid:31277064
    CrossRefPubMed
  4. 4.↵
    1. Ito H,
    2. Yamamoto K,
    3. Fukutake S, et al
    . Two-year follow-up results of magnetic resonance imaging-guided focused ultrasound unilateral thalamotomy for medication-refractory essential tremor. Intern Med 2020;59:2481–83 doi:10.2169/internalmedicine.4360-19 pmid:32641664
    CrossRefPubMed
  5. 5.↵
    1. Martinez-Fernandez R,
    2. Mahendran S,
    3. Pineda-Pardo JA, et al
    . Bilateral staged magnetic resonance-guided focused ultrasound thalamotomy for the treatment of essential tremor: a case series study. J Neurol Neurosurg Psychiatry 2021;92:927–31 doi:10.1136/jnnp-2020-325278 pmid:33906933
    Abstract/FREE Full Text
  6. 6.↵
    1. Elias WJ,
    2. Lipsman N,
    3. Ondo WG, et al
    . A randomized trial of focused ultrasound thalamotomy for essential tremor. N Engl J Med 2016;375:730–39 doi:10.1056/NEJMoa1600159 pmid:27557301
    CrossRefPubMed
  7. 7.↵
    1. Odeen H,
    2. Parker DL
    . Improved MR thermometry for laser interstitial thermotherapy. Lasers Surg Med 2019;51:286–300 doi:10.1002/lsm.23049 pmid:30645017
    CrossRefPubMed
  • Received October 16, 2023.
  • Accepted after revision December 4, 2023.
  • © 2024 by American Journal of Neuroradiology
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 45 (3)
American Journal of Neuroradiology
Vol. 45, Issue 3
1 Mar 2024
  • Table of Contents
  • Index by author
  • Complete Issue (PDF)
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
MR-Guided Focused Ultrasound Thalamotomy in the Setting of Aneurysm Clip
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
Henrik Odéen, Lubdha M Shah, Viola Rieke, Dennis L Parker, Shervin Rahimpour
MR-Guided Focused Ultrasound Thalamotomy in the Setting of Aneurysm Clip
American Journal of Neuroradiology Mar 2024, 45 (3) 302-304; DOI: 10.3174/ajnr.A8109

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
MRgFUS Thalamotomy with Aneurysm Clip
Henrik Odéen, Lubdha M Shah, Viola Rieke, Dennis L Parker, Shervin Rahimpour
American Journal of Neuroradiology Mar 2024, 45 (3) 302-304; DOI: 10.3174/ajnr.A8109
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • SUMMARY:
    • ABBREVIATIONS:
    • DISCUSSION
    • CONCLUSIONS
    • Footnotes
    • References
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • Mechanic Thrombectomy with ANA Device: ANAIS Study
  • Pipeline Vantage Flow Diverter for Aneurysms
  • Vascular Injury After Stent Retriever Retraction
Show more Neurointervention

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editors Choice
  • Fellow Journal Club
  • Letters to the Editor

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

Special Collections

  • Special Collections

Resources

  • News and Updates
  • Turn around Times
  • Submit a Manuscript
  • Author Policies
  • Manuscript Submission Guidelines
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Submit a Case
  • Become a Reviewer/Academy of Reviewers
  • Get Peer Review Credit from Publons

Multimedia

  • AJNR Podcast
  • AJNR SCANtastic
  • Video Articles

About Us

  • About AJNR
  • Editorial Board
  • Not an AJNR Subscriber? Join Now
  • Alerts
  • Feedback
  • Advertise with us
  • Librarian Resources
  • Permissions
  • Terms and Conditions

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire