Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • Video Articles
    • AJNR Case Collection
    • Case of the Week Archive
    • Case of the Month Archive
    • Classic Case Archive
  • Special Collections
    • AJNR Awards
    • Low-Field MRI
    • Alzheimer Disease
    • ASNR Foundation Special Collection
    • Photon-Counting CT
    • View All
  • Multimedia
    • AJNR Podcasts
    • AJNR SCANtastic
    • Trainee Corner
    • MRI Safety Corner
    • Imaging Protocols
  • For Authors
    • Submit a Manuscript
    • Submit a Video Article
    • Submit an eLetter to the Editor/Response
    • Manuscript Submission Guidelines
    • Statistical Tips
    • Fast Publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Imaging Protocol Submission
    • Author Policies
  • About Us
    • About AJNR
    • Editorial Board
    • Editorial Board Alumni
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

AJNR Awards, New Junior Editors, and more. Read the latest AJNR updates

Research ArticlePatient Safety

Reduction of Radiation Dose and Scanning Time While Preserving Diagnostic Yield: A Comparison of Battery-Powered and Manual Bone Biopsy Systems

S. Kihira, C. Koo, A. Lee, A. Aggarwal, P. Pawha and A. Doshi
American Journal of Neuroradiology February 2020, DOI: https://doi.org/10.3174/ajnr.A6428
S. Kihira
aFrom the Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, New York.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for S. Kihira
C. Koo
aFrom the Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, New York.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for C. Koo
A. Lee
aFrom the Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, New York.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for A. Lee
A. Aggarwal
aFrom the Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, New York.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for A. Aggarwal
P. Pawha
aFrom the Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, New York.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for P. Pawha
A. Doshi
aFrom the Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, New York.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for A. Doshi
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

Article Figures & Data

Figures

  • Tables
  • FIG 1.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIG 1.

    Bone biopsy of lytic bone lesions with manual and battery-powered drills. A, A 74-year-old man with multiple myeloma undergoing CT-guided biopsy of a right iliac lytic lesion with the Osteo-site manual system. CT image shows placement of the needle into the right iliac lytic lesion. B, A 58-year-old man with multiple myeloma undergoing CT-guided biopsy of a lytic L3 lesion with the OnControl battery-powered system. CT image shows placement of needle into the L3 vertebral body.

  • FIG 2.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIG 2.

    Breakdown of the final pathology diagnosis in various bone lesion classes: all bone lesions (A), lytic lesions (B), sclerotic lesions (C), and suspected infectious lesions (D).

Tables

  • Figures
    • View popup
    Table 1:

    Demographic characteristics of patients undergoing bone biopsiesa

    TotalManualBattery-PoweredP Value
    No.585314271
    Age (mean ± SD)62 ± 1362 ± 1361 ± 12.541
    Sex (M/F)305:280173:141132:139.135
    Suspected origin of primary disease.103
     Boneb41.7 (244)38.9 (122)45 (122)
     Prostate3.8 (22)4.5 (14)3.0 (8)
     Breast10.4 (61)11.5 (36)9.2 (25)
     Lung2.9 (17)4.8 (15)0.7 (2)
     Kidney0.7 (4)1.0 (3)0.4 (1)
     Systemicc0.7 (4)1.0 (3)0.4 (1)
     Liver0.3 (2)0.6 (2)0 (0)
     Bladder1.7 (10)1.6 (5)1.8 (5)
     Miscellaneousd8.5 (50)9.2 (29)7.7 (21)
     Unestablished/unknowne27 (158)24.8 (78)29.5 (80)
     Blood2.2 (13)2.2 (7)2.2 (6)
    Location of bone lesion.16
     Vertebral column47.0 (275)45.2 (142)49.1 (133)
      Cervical0.6 (4)0.1 (4)0 (0)
      Thoracic17.9 (105)16.2 (51)19.9 (54)
      Lumbar17.3 (101)17.5 (55)17.0 (46)
      Sacral11.1 (65)10.2 (32)12.2 (33)
     Pelvis36.9 (216)39.5 (124)33.9 (92)
     Extremity8.4 (49)10.5 (33)5.9 (16)
     Miscellaneousf0.5 (3)0.6 (2)0.4 (1)
     Disc7.2 (42)4.1 (13)10.7 (29)
    • ↵a Values for frequency of suspected origin of primary disease and lesion location represent percentages followed by total number of cases in parentheses.

    • ↵b Primary bone lesions include suspected multiple myeloma from laboratory testing.

    • ↵c Predominantly sarcoidosis.

    • ↵d Includes thyroid, salivary gland, vulvar, tongue, melanoma, and anal cancers.

    • ↵e Includes all cases without known malignancy or suspected primary bone lesion.

    • ↵f Includes sternum, ribs, clavicle, scapula, calvaria, and tarsal bones.

    • View popup
    Table 2:

    Comparative performance of the drill systems in various lesion classificationsa

    Diagnostic YieldCrush ArtifactsRadiation Dose (mGy × cm2)Scanning Time (min)
    Lytic lesions
     Manual83.4 (201/241)5 (12/241)84542
     Battery-powered89.0 (161/181)7.7 (14/181)65735
     P value.069.168.001b.001b
    Sclerotic lesions
     Manual76.4 (42/55)7.3 (4/55)106144
     Battery-powered89.1 (49/55)7.3 (4/55)80437
     P value.0641.028b.012b
    Infectious lesions
     Manual50.0 (9/18)11.1 (2/18)111346
     Battery-powered51.4 (18/35)0 (0/35)81139
     P value.576.111.155.128
    All lesions
     Manual80.3 (252/314)5.7 (18/314)90043
     Battery-powered84.1 (228/271)6.6 (18/271)70436
     P value.538.387.001b.001b
    • ↵a Percentage followed by the number of cases/total number of cases in parentheses for diagnostic yield and crush artifacts. Mean values are listed for radiation dose and scanning time.

    • ↵b Significant P value (P < .05).

    • View popup
    Table 3:

    Comparative performance of drill systems in sclerotic lesions based on densitya

    Density (HU)Diagnostic YieldCrush ArtifactsRadiation Dose (mGy × cm2)Scanning Time (min)
    Manual
     250–70088.5 (23/26)3.8 (1/26)104445.1
     >70085.7 (12/14)2.1 (3/14)131746.1
     P value.583.115.3.862
    Battery-powered
     250–70089.3 (25/28)0 (0/28)88934.6
     >70085 (17/20)20 (4/20)75241
     P value.562.025b.38.026b
    • ↵a Percentage followed by number of cases/total number of cases in parentheses for diagnostic yield and crush artifacts. Mean values are listed for radiation dose and scanning time.

    • ↵b Significant P value (P < .05).

PreviousNext
Back to top
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Reduction of Radiation Dose and Scanning Time While Preserving Diagnostic Yield: A Comparison of Battery-Powered and Manual Bone Biopsy Systems
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
S. Kihira, C. Koo, A. Lee, A. Aggarwal, P. Pawha, A. Doshi
Reduction of Radiation Dose and Scanning Time While Preserving Diagnostic Yield: A Comparison of Battery-Powered and Manual Bone Biopsy Systems
American Journal of Neuroradiology Feb 2020, DOI: 10.3174/ajnr.A6428

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Reduction of Radiation Dose and Scanning Time While Preserving Diagnostic Yield: A Comparison of Battery-Powered and Manual Bone Biopsy Systems
S. Kihira, C. Koo, A. Lee, A. Aggarwal, P. Pawha, A. Doshi
American Journal of Neuroradiology Feb 2020, DOI: 10.3174/ajnr.A6428
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Purchase

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSIONS
    • Footnotes
    • References
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

Patient Safety

  • Safety of Intrathecal Gadobutrol in Various Doses
  • Impact of Kidney Function on CNS Gadolinium Deposition in Patients Receiving Repeated Doses of Gadobutrol
  • Contrast-Induced Acute Kidney Injury in Radiologic Management of Acute Ischemic Stroke in the Emergency Setting
Show more Patient Safety

Neurointervention

  • A Retrospective Study in Tentorial DAVFs
  • Proximal Protection Devices for Carotid Stenting
  • Rescue Reentry in Carotid Near-Occlusion
Show more Neurointervention

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editor's Choice
  • Fellows' Journal Club
  • Letters to the Editor
  • Video Articles

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

More from AJNR

  • Trainee Corner
  • Imaging Protocols
  • MRI Safety Corner
  • Book Reviews

Multimedia

  • AJNR Podcasts
  • AJNR Scantastics

Resources

  • Turnaround Time
  • Submit a Manuscript
  • Submit a Video Article
  • Submit an eLetter to the Editor/Response
  • Manuscript Submission Guidelines
  • Statistical Tips
  • Fast Publishing of Accepted Manuscripts
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Author Policies
  • Become a Reviewer/Academy of Reviewers
  • News and Updates

About Us

  • About AJNR
  • Editorial Board
  • Editorial Board Alumni
  • Alerts
  • Permissions
  • Not an AJNR Subscriber? Join Now
  • Advertise with Us
  • Librarian Resources
  • Feedback
  • Terms and Conditions
  • AJNR Editorial Board Alumni

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire