Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • AJNR Case Collection
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • Special Collections
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
    • 2024 AJNR Journal Awards
    • Most Impactful AJNR Articles
  • Multimedia
    • AJNR Podcast
    • AJNR Scantastics
    • Video Articles
  • For Authors
    • Submit a Manuscript
    • Author Policies
    • Fast publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Manuscript Submission Guidelines
    • Imaging Protocol Submission
    • Submit a Case for the Case Collection
  • About Us
    • About AJNR
    • Editorial Board
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Other Publications
    • ajnr

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • AJNR Case Collection
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • Special Collections
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
    • 2024 AJNR Journal Awards
    • Most Impactful AJNR Articles
  • Multimedia
    • AJNR Podcast
    • AJNR Scantastics
    • Video Articles
  • For Authors
    • Submit a Manuscript
    • Author Policies
    • Fast publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Manuscript Submission Guidelines
    • Imaging Protocol Submission
    • Submit a Case for the Case Collection
  • About Us
    • About AJNR
    • Editorial Board
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

Welcome to the new AJNR, Updated Hall of Fame, and more. Read the full announcements.


AJNR is seeking candidates for the position of Associate Section Editor, AJNR Case Collection. Read the full announcement.

 

Getting new auth cookie, if you see this message a lot, tell someone!
EditorialEDITORIAL

The High-Field-Strength Curmudgeon

Jeffrey S. Ross
American Journal of Neuroradiology February 2004, 25 (2) 168-169;
Jeffrey S. Ross
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

I undertook this assignment, to muse on the state of current 3T clinical imaging, with trepidation because, depending on the phase of the moon, I vacillate between wild unjustified, undocumented optimism of the technology and the opposite extreme of sounding like a fossilized curmudgeon incapable of appreciating technology (or, even worse, of not having the “vision thing”). Our 3T system (head only) was installed in June 2001 and runs half-time clinical, half-time research. Because this magnet replaced an aging (yet full-time) clinical system, considerable pressure exists to use it as efficiently as possible for a wide variety of clinical cases. This clinical caseload has not been viewed with excitement by the technologists, who by necessity know the foibles of the individual MR systems more thoroughly than do the neuroradiologists. Their enthusiasm for our 3T system is running slightly short that of spending a night at the Bates Motel.

The possibilities of 3T imaging have captured the imagination of radiologists and the spreadsheets of the manufacturers. The ongoing debate of low versus mid versus high field strength (1.5T) is now elongated to 3T and beyond. What is the reality of current 3T clinical imaging? The operative word is “clinical,” and few sites perform routine protocols, in routine time slots, at this higher field strength for purely clinical reasons. 3T is not presently at the level of mainstream “bread-and-butter” imaging. To undertake a 3T system in a strictly clinical environment begs for, if not trouble, then intense dissatisfaction and a lot of time talking to “Applications.” A clinical system needs to provide excellent image quality quickly and with a minimum of fuss. The concept of good image quality does not refer only to a high-resolution, heavily T2-weighted image but rather the full gamut of T1-weighted spin-echo, balanced, T2-weighted, and more specialized sequences needed in a daily practice. For brain imaging, the ability to produce a high-resolution coronal T2-weighted image of the hippocampus does not validate the complete imaging package at 3 T. The 1.5T platforms have a long history with multiple manufacturers, and the broad expanse of optimized sequences available at 1.5T does not seamlessly transition to the 3T realm.

The hype and promise of 3T relates to the increased signal-to-noise ratio of the higher field strength. Magnetization increases as the square of the field strength, while noise increases linearly giving a potential doubling of signal to noise from 1.5 to 3.0T. This increased signal-to-noise capital can be traded off for higher resolution images at comparable imaging times to 1.5T, better quality perfusion/diffusion studies, or spent for quicker examination times. In reality, this doubling of signal-to-noise ratio has been illusive. Frayne et al did not find the expected doubling of signal-to-noise ratio at 3.0T but an increase on the order of 30–60% (1).

In daily practice, we have not been able to achieve a reduction in overall imaging time because of the constraints of the longer T1 relaxation at the high field and power deposition (2). Producing T2-weighted images is the easy part, and good-quality, high-resolution images are readily obtained at 3.0 T. A reversed T2-weighted image has been encouraged for use on 3T systems as a single encompassing sequence (3). I am loath to give up the multiplicity of sequences that has served us so well, for so long.

T1-weighted images are a much different story. The prolonged T1 at 3T has necessitated the use of either a gradient echo T1-weighted image or an inversion recovery sequence to obtain reasonable gray matter—white matter differentiation. The constraints of power deposition (increasing as the square of the field strength) at the higher field translate into fewer sections with less anatomic coverage. This requires an interleaved sequence, doubling T1-weighted image examination time. T1-weighted image quality is degraded by the increased amount of chemical shift artifact at the higher field. One can obviate this by replacing the conventional T1 with a 3D gradient echo T1-weighted image, but because this is not standard for us at the workhorse field strength of 1.5 T, why should it all of a sudden be acceptable at 3 T?

Limitations also arise in our head-only system because of coil design that distorts the periphery of the images and mandates precise head positioning to achieve optimum signal-to-noise ratio. The images are suboptimal for clinical situations, requiring a high degree of spatial uniformity, such as preoperative stereotactic localization studies, which we still perform on the 1.5T systems. Granted, these problems should be diminished with coil and magnet design improvements and are not such a significant issue on whole-body 3T systems. On the plus side, this inherent problem of the head-only system does relieve one of having to comment on upper cervical degenerative disk disease on the sagittal images, because it is not visible!

Spectroscopy has not yielded a quantum improvement despite the potential of a 100% improvement going from 1.5 to 3.0T, with its improved signal-to-noise ratio and larger chemical shift. Improvements from 20–50% in signal-to-noise ratio can be seen at the higher field strength because of problems related to shortened T2, field inhomogeneities, and increased line width (4, 5).

Not to be a labeled a complete Luddite, immediate improvements can be seen at 3T with nearly any gradient echo technique, such as MR angiography (MRA) and 3D gradient echo sequences. Contrast-enhanced MRA has also been successful demonstrated at 3.0T (6). Susceptibility effects have been surprisingly limited, and diffusion image quality has been very good. Blood oxygenation level–dependent functional imaging studies are excellent, although it is difficult to sell a system to a community hospital on the basis of volume of fMRI studies. In the end, 3T is an evolutionary, not revolutionary, technology. As such, growing pains are to be expected and will be overcome in the future. Five years would be a reasonable time line for full maturation of this technology. In the shorter term, however, I would be cautious about a technology driven by manufacturers and academics when your patient referral base is at stake.

References

  1. ↵
    Frayne R, Goodyear BG, Dickhoff P, et al. Magnetic resonance imaging at 3.0 Tesla: challenges and advantages in clinical neurological imaging. Invest Radiol 2003;38:385–402
    CrossRefPubMed
  2. ↵
    Ruggieri PM, Tkach J, Ross JS, Masaryk TJ. Routine clinical imaging at 3.0T: an oxymoron? Radiology 2002;225:430
  3. ↵
    Fujii Y, Nakayama N, Nakada T. High-resolution T2 reversed magnetic resonance imaging on high magnetic field system. J Neurosurg 1998;89:492–495
    PubMed
  4. ↵
    Barker PB, Hearshen DO, Boska MD. Single-voxel proton MRS of the human brain at 1.5T and 3.0T. Magn Res Med 2001;45:765–769
    CrossRefPubMed
  5. ↵
    Gonen O, Gruber S, Li BS, et al. Multivoxel 3D proton spectroscopy in the brain at 1.5T versus 3.0T: signal-to-noise ratio and resolution comparison. AJNR Am J Neuroradiol 2001;22:1727–1731
    Abstract/FREE Full Text
  6. ↵
    Bernstein MA, Huston J III, Lin C, et al. High-resolution intracranial and cervical MRA at 3.0T: technical considerations and initial experience. Magn Reson Med 2001;46:955–962
    CrossRefPubMed
  • Copyright © American Society of Neuroradiology
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 25 (2)
American Journal of Neuroradiology
Vol. 25, Issue 2
1 Feb 2004
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
The High-Field-Strength Curmudgeon
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
Jeffrey S. Ross
The High-Field-Strength Curmudgeon
American Journal of Neuroradiology Feb 2004, 25 (2) 168-169;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
The High-Field-Strength Curmudgeon
Jeffrey S. Ross
American Journal of Neuroradiology Feb 2004, 25 (2) 168-169;
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • References
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • High-Resolution 3D-Constructive Interference in Steady-State MR Imaging and 3D Time-of-Flight MR Angiography in Neurovascular Compression: A Comparison between 3T and 1.5T
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • Supporting Imaging Research: A Framework for Equity and Excellence in Neuroradiology
  • The Generation Gap in Work Values Has Hit Medical Training
  • Unveiling the New Digital AJNR: Personalized and Interactive
Show more EDITORIAL

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editors Choice
  • Fellow Journal Club
  • Letters to the Editor

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

Special Collections

  • Special Collections

Resources

  • News and Updates
  • Turn around Times
  • Submit a Manuscript
  • Author Policies
  • Manuscript Submission Guidelines
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Submit a Case
  • Become a Reviewer/Academy of Reviewers
  • Get Peer Review Credit from Publons

Multimedia

  • AJNR Podcast
  • AJNR SCANtastic
  • Video Articles

About Us

  • About AJNR
  • Editorial Board
  • Not an AJNR Subscriber? Join Now
  • Alerts
  • Feedback
  • Advertise with us
  • Librarian Resources
  • Permissions
  • Terms and Conditions

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire