Skip to main content
Advertisement

Main menu

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • AJNR Case Collection
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • Special Collections
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
    • 2024 AJNR Journal Awards
    • Most Impactful AJNR Articles
  • Multimedia
    • AJNR Podcast
    • AJNR Scantastics
    • Video Articles
  • For Authors
    • Submit a Manuscript
    • Author Policies
    • Fast publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Manuscript Submission Guidelines
    • Imaging Protocol Submission
    • Submit a Case for the Case Collection
  • About Us
    • About AJNR
    • Editorial Board
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Other Publications
    • ajnr

User menu

  • Alerts
  • Log in

Search

  • Advanced search
American Journal of Neuroradiology
American Journal of Neuroradiology

American Journal of Neuroradiology

ASHNR American Society of Functional Neuroradiology ASHNR American Society of Pediatric Neuroradiology ASSR
  • Alerts
  • Log in

Advanced Search

  • Home
  • Content
    • Current Issue
    • Accepted Manuscripts
    • Article Preview
    • Past Issue Archive
    • AJNR Case Collection
    • Case of the Week Archive
    • Classic Case Archive
    • Case of the Month Archive
  • Special Collections
    • Spinal CSF Leak Articles (Jan 2020-June 2024)
    • 2024 AJNR Journal Awards
    • Most Impactful AJNR Articles
  • Multimedia
    • AJNR Podcast
    • AJNR Scantastics
    • Video Articles
  • For Authors
    • Submit a Manuscript
    • Author Policies
    • Fast publishing of Accepted Manuscripts
    • Graphical Abstract Preparation
    • Manuscript Submission Guidelines
    • Imaging Protocol Submission
    • Submit a Case for the Case Collection
  • About Us
    • About AJNR
    • Editorial Board
  • More
    • Become a Reviewer/Academy of Reviewers
    • Subscribers
    • Permissions
    • Alerts
    • Feedback
    • Advertisers
    • ASNR Home
  • Follow AJNR on Twitter
  • Visit AJNR on Facebook
  • Follow AJNR on Instagram
  • Join AJNR on LinkedIn
  • RSS Feeds

Welcome to the new AJNR, Updated Hall of Fame, and more. Read the full announcements.


AJNR is seeking candidates for the position of Associate Section Editor, AJNR Case Collection. Read the full announcement.

 

Research ArticleINTERVENTIONAL

Observer Agreement in the Assessment of Endovascular Aneurysm Therapy and Aneurysm Recurrence

H.J. Cloft, T. Kaufmann and D.F. Kallmes
American Journal of Neuroradiology March 2007, 28 (3) 497-500;
H.J. Cloft
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
T. Kaufmann
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
D.F. Kallmes
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF
Loading

Abstract

BACKGROUND AND PURPOSE: Assessments of completeness of endovascular cerebral aneurysm therapy are commonly reported in the literature. We studied several aneurysm assessment scales with regard to observer variability, which directly affects validity of these scales.

MATERIALS AND METHODS: Initial aneurysm occlusion and occlusion at a follow-up angiogram at 3–6 months were assessed independently by 2 experienced observers. Assessments of each aneurysm were made using 3 different scales: 4-response (complete, dog ear, neck remnant, incomplete), 3-response (complete, near-complete, incomplete), and 2-response (complete or near-complete, incomplete). Assessments were also made of comparisons of initial treatment angiogram with follow-up angiogram using 2 different scales: 3-response (better, same, worse) and 2-point response (not worse, worse).

RESULTS: With assessments of both initial and follow-up angiograms, interobserver and intraobserver agreement was progressively worse with increasing response choices in the scales. Observer agreement on assessments of initial angiograms (κ values 0.48–0.67) was worse than that for follow-up angiograms (κ values 0.66–0.97). For the comparisons of the initial angiogram with the follow-up angiogram, there was worse observer agreement with the 3-response scale (κ values 0.64–0.71) than with the 2-response scale (κ values 0.78–0.89).

CONCLUSION: Interobserver and intraobserver variability are inherent to assessment scales of completeness of cerebral aneurysm therapy. Observer variability is substantially better in scales that offer fewer observer responses. However, scales with fewer observer responses may not identify aneurysm subgroups that have differing risks of recurrence and/or rehemorrhage.

The goal of endovascular therapy of cerebral aneurysms is to eliminate blood flow to as much of the aneurysm as can safely be achieved. Completeness of occlusion of an aneurysm is commonly used as a measure of the success of therapy. Angiographic assessments of completeness of aneurysm therapy have been widely used but never formally validated. Raymond et al1,2 described a scale with 4 categories: “complete,” “dog ear,” “residual neck,” and “residual aneurysm.” Perhaps because of subjectivity in classifying aneurysms as “residual neck” and “residual aneurysm,” and an uncertainty about the clinical relevance of such a discrimination, Raymond et al3 later simplified their scheme to 3 classifications; “complete,” “residual neck,” and “residual aneurysm.” Murayama et al4 classified completeness of aneurysm therapy as “complete,” “neck remnant,” and “incomplete.” Other authors have described a classification based on percentage of aneurysm filling (eg, “>90% occlusion”5–8 or “>95% occlusion”9–11). Such percentages are based not on any real quantitative measurement but on subjective assessments not inherently different from those described by Raymond et al1–3 and Murayama et al.4

As new technology emerges that offers potential improvements in completeness and durability of cerebral aneurysm therapy, it becomes more important to validate scales used for assessment of aneurysm therapy. Valid assessments of completeness and durability of aneurysm therapy will be needed to judge the efficacy of such new technology in clinical trials. Thus, we undertook a study to assess the observer variability in several scales that assess the completeness of aneurysm therapy and change in completeness of aneurysm occlusion on follow-up angiography.

Materials and Methods

Aneurysms Studied and Readers

Angiograms from a total of 125 aneurysms obtained immediately before and after endovascular therapy and 83 angiograms obtained 3 to 6 months after endovascular therapy were assessed using the scales described below. These angiograms were obtained in the course of the HydroCoil for Endovascular Aneurysm Occlusion (HEAL) registry. Each angiogram was assessed by 2 readers who were interventional neuroradiologists (H.J.C. and D.F.K.), each with more than 7 years of experience with endovascular aneurysm therapy. Both readers were employed at the same institution and worked closely together. Each reader made assessments on 2 occasions separated by at least 30 days in an attempt to diminish recall bias. The readers had not participated in the treatment of any of the aneurysms included in the study, and they were blinded to all patient information other than the images to be read. Each reader was blind to the other observer's assessments and to his own previous assessments.

Assessment Scales

Each initial post-treatment angiogram and each 3–6-month follow-up angiogram was assessed using 3 different scales of completeness of aneurysm therapy. The 4-response scale included the categories “complete,” “dog ear,” “residual neck,” and “residual aneurysm,” as described previously.1,2 The 3-response scale included the categories “complete,” “near-complete,” and “incomplete.” The 2-response scale included the categories “complete or near-complete,” and “incomplete.” Change between initial postprocedure angiograms and follow-up angiograms was assessed using 2 scales. The 3-response scale included the categories “better,” “same,” and “worse.” The 2-response scale included the categories “not worse” and “worse.”

Statistical Analysis.

Proportion of concordant readings (p) and κ statistics were calculated to determine the relative interobserver and intraobserver agreement of the various aneurysm assessment scales. The proportion of concordant readings was calculated as the number of concordant readings divided by the total number of readings. Simple κ values were determined for assessments that had 2 responses, and weighted κ values were determined for assessments that had more than 2 possible responses. The statistical analysis was performed by using SAS 8.02 software (SAS Institute, Cary, NC).

The κ values obtained were interpreted relative to the criteria of Fleiss.12 According to Fleiss, values ≤0.40 represent poor agreement, values between 0.40 and 0.75 represent fair to good agreement, and values >0.75 represent excellent agreement.

Results

The results are summarized in Tables 1 and 2.

View this table:
  • View inline
  • View popup
Table 1:

Comparison of interobserver agreement for assessment of aneurysm treatment using 4-, 3-, and 2-response scales and “better/same/worse” scale

View this table:
  • View inline
  • View popup
Table 2:

Comparison of intraobserver agreement for assessment of aneurysm treatment using 4-, 3-, and 2-response scales, and “better/same/ worse” scale

Angiographic Completeness of Aneurysm Therapy

In general, scales with more allowable responses were associated with less agreement than scales with fewer allowable responses. The 4-response scale yields the least interobserver and intraobserver agreement for both the initial angiogram and the follow-up angiogram. The 3-response scale yields more agreement than the 4-response scale. The 2-response scale yields more agreement than the 3-response scale.

Intraobserver agreement, stated as κ, for follow-up angiograms assessed with the 4-response and 3-response scales ranged from 0.75 to 0.78, whereas for interobserver agreement, they ranged from 0.66 to 0.67. This indicates less interobserver than intraobserver agreement in the categorization of aneurysms when more choices are available in the scale.

For initial postprocedure angiogram assessments, the κ values for interobserver and intraobserver comparisons were 0.48 to 0.67 for all scales used. For follow-up angiogram assessments, the κ values for interobserver and intraobserver comparisons were 0.66 to 0.97 for all scales used. Thus, both interobserver and intraobserver agreement was better on follow-up angiograms than initial angiograms for all scales used. Examples of cases with discordant readings are shown in Fig 1.

Fig 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Fig 1.

Examples of observer variability in the assessment of completeness of cerebral aneurysm therapy. A carotid aneurysm before (A) and immediately after (B) endovascular therapy, which was assessed variably as “complete,” “dog ear,” and “incomplete.”

Assessment of Change at Follow-up Angiogram

For assessments of angiographic change on the follow-up angiogram relative to the initial angiogram, the κ values for interobserver and intraobserver comparisons were 0.64 to 0.71 for the “better, same, worse” scale, whereas they were 0.78 to 0.89 for the “not worse, worse” scale.

Discussion

Our study elucidates the observer variability inherent in the angiographic assessment of completeness of cerebral aneurysm therapy. With assessments of both initial and follow-up angiograms for completeness of aneurysm therapy, interobserver and intraobserver agreement was progressively worse with increasing response choices in the aneurysm assessment scale. Likewise, for the comparisons of the initial angiogram to the follow-up angiogram, there was worse observer agreement with the 3-response (“better, same, worse”) scale than with the 2-response (“not worse, worse”) scale. These findings are supported by previous work demonstrating that the value of κ tends to increase as the number of categories is decreased, thus indicating better agreement when fine distinctions are eliminated.13

There was less agreement on initial angiograms than on 3–6-month follow-up angiograms. This finding can be explained by a high degree of subjectivity in the assessment of areas within an aneurysm that still fill with contrast material immediately after endovascular aneurysm therapy. The interpreter is left to guess whether these areas will thrombose over the next few hours.

Our study used 2 readers of very similar training and practice background. Interobserver variability between readers with more varied backgrounds might be even higher.

The degree of aneurysm occlusion after endovascular therapy is really a continuous variable. Therefore, commonly used scales for grading the degree of aneurysm occlusion apply an ordinal scale on what is really a continuous variable. This system forces a reader to categorize an outcome into a discrete category, which is rather subjective and can contribute to observer variability (Fig 1). This practice evolved because it is quite difficult to accurately quantify the continuous variable of “completeness of aneurysm occlusion” using 2-dimensional images of irregular 3D objects. The creation of ordinal categories forces the image interpreter to subjectively categorize the completeness of aneurysm treatment into one of the categories based on 2-dimensional images. 3D angiographic imaging now available might provide a more quantitative assessment of aneurysm occlusion, but standardized performance of such 3D measurement techniques is not currently developed enough to be practical for use on all, or even most, of the angiographic equipment used at each of the medical centers that might participate in a multicenter study of aneurysm therapy. Thus, the use of ordinal scales for the assessment of completeness of aneurysm occlusion remains as an important tool that potentially allows for the comparison of treatment data from multiple medical centers and multiple studies.

Because cerebral aneurysm therapy is intended to prevent subarachnoid hemorrhage, the future risk of hemorrhage from a cerebral aneurysm is ideally what would be measured to judge the success of therapy. Because endovascular therapy is rather successful at preventing subarachnoid hemorrhage, hemorrhagic events in these patients are quite uncommon. With such a low event rate for subarachnoid hemorrhage after endovascular therapy, studies of very large numbers of patients over a number of years would be necessary for rate of subarachnoid hemorrhage to be a practical outcome measure. The International Subarachnoid Aneurysm Trial (ISAT)14 is a trial that has enrolled enough patients (1073 treated with coils) and follows them over a long enough period of time (at least 5 years) that it can make a meaningful assessment of the rehemorrhage rate. However, it is not practical for all studies of outcomes of endovascular cerebral aneurysm therapy to be so large. Thus, investigators use completeness of coil therapy and angiographic recurrence as surrogate markers for risk of future hemorrhage, making the assumption that risk of future hemorrhage correlates with degree of persistent filling of the aneurysm with contrast during angiography.

Another factor that makes assessment of degree of aneurysm occlusion important is that the completeness of aneurysm therapy at the time of treatment is somewhat predictive of subsequent risk of recurrence. For aneurysms that were angiographically completely treated, Murayama et al4 reported a recurrence rate of 1.1% for small aneurysms with small necks, 12.5% for small aneurysms with wide necks, and 20% in large aneurysms. For aneurysms with a neck remnant, the recurrence rates were 7.7% for small aneurysms with small necks, 29.4% for small aneurysms with wide necks, and 44.4% for large aneurysms. Raymond et al3 reported major recurrence rates of 9% for aneurysms initially completely occluded, 23% for aneurysms with residual neck, and 47% for aneurysms with residual aneurysm. Thornton et al11 reported a recurrence rate of 1.8% for aneurysms that were “100%” occluded, and 26% for aneurysms with “residual neck.” As an aneurysm progressively recanalizes after endovascular therapy, the degree of protection of the patient from rehemorrhage is expected to decrease. Because the presence of a residual neck is predictive of future recanalization, it is a worthwhile distinction to make.

Scales with fewer observer responses may not identify aneurysm subgroups that have differing risks of recurrence and/or rehemorrhage. Without identification of lesser degrees of aneurysm remnant and recurrence, it would not be possible to ascertain such issues as the extent to which a minor recurrence predicts a higher risk of future hemorrhage and the risk that a minor recurrence will turn into a major recurrence. In choosing a scale for use in a trial of endovascular aneurysm therapy, a balance must be struck between reducing observer variability by offering fewer responses and improving identification of important subgroups by offering more responses.

Change in degree of aneurysm occlusion on follow-up angiography is a critical variable to record because it specifically assesses the major weakness of endovascular therapy relative to surgery (ie, aneurysm recurrence). Scales of degree of aneurysm occlusion can be deceptive with regard to recurrence, because an aneurysm may have a worsening degree of occlusion at follow-up angiography, yet it may not change categories on a grading scale. For example, an aneurysm treated and initially classified as “residual aneurysm” may show interval increase in the size of the residual aneurysm cavity at follow-up angiography and yet remain classified simply as “residual aneurysm”; ie, the degree of occlusion of the aneurysm changes, but the classification does not. Raymond et al3 defined a recurrence as “any increase in size of the remnant” and defined a recurrence as “major” if “it was saccular and its size would theoretically permit retreatment with coils.” Murayama et al4 defined “recanalization” as a “more than 10% increase in contrast filling of the aneurysm.” We chose to make the assessments as objective as possible by making the scales qualitative rather than quantitative.

One might suspect that an important marker of failure of aneurysm therapy is the need for retreatment of the aneurysm. The necessity of aneurysm retreatment, however, is not something that can be objectively measured as an end point for scientific research. The decision to retreat is quite subjective in many cases. The risk of treating relative to not treating a recurrent aneurysm can be quite difficult to ascertain in many cases, because the risk of future rupture of a given partially treated aneurysm is largely unknown. In our experience, recurrences are often more technically challenging to treat than the original, untreated aneurysm. Physicians vary greatly in terms of how aggressively they would treat an aneurysm recurrence with balloon remodeling, an adjunctive stent, or perhaps referral for surgery. Patients may refuse retreatment for a variety of reasons. The treating physician might have subjective reservations about further therapy based on experiences at the time of treatment (“you had to be there”) or based on intimate knowledge of the patient (“you have to know this patient”). The operating physician may be biased against retreating an aneurysm that he or she originally treated because of an unwillingness to admit failure of treatment. Conversely, a physician may be biased toward retreating an aneurysm that he or she originally treated because of a perception of the recurrence as a personal failure that he or she would like to confront. Ideally, such personal biases should be left out of patient care decisions, but they undoubtedly have some effect on management decisions. With so much uncertainty, bias, and subjectivity, simply tallying whether an aneurysm is retreated has little value in scientifically assessing the success of aneurysm treatment.

Scales to assess angiographic completeness of aneurysm therapy and recurrence will continue to be necessary for the development of new endovascular therapies. Such scales are of critical importance in assessing the efficacy of new aneurysm therapies in clinical trials. To minimize bias, assessment of angiogram studies of aneurysm treatment should be made by a central reader rather than the treating physician. Because of the potential for interobserver variability, especially with assessment scales with more than 2 responses, it may be useful to have more than 1 reader make the assessments and to have readers try to review difficult cases together to reach consensus.

Conclusions

Both interobserver and intraobserver variability are inherent to assessment scales of completeness of cerebral aneurysm therapy. Observer variability is substantially lower in scales that offer fewer observer responses. However, scales with fewer observer responses may not identify aneurysm subgroups that have differing risks of recurrence and/or rehemorrhage. These limitations must be considered when using such scales in clinical trials that assess the efficacy of endovascular cerebral aneurysm treatment.

References

  1. ↵
    Raymond J, Roy D, Bojanowski M, et al. Endovascular treatment of acutely ruptured and unruptured aneurysms of the basilar bifurcation. J Neurosurg 1997;86:211–19
    PubMed
  2. ↵
    Roy D, Raymond J, Bouthillier A, et al. Endovascular treatment of ophthalmic segment aneurysms with Guglielmi detachable coils. AJNR Am J Neuroradiol 1997;18:1207–15
    Abstract
  3. ↵
    Raymond J, Guibert F, Weill A, et al. Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils. Stroke 2003;34:1398–403
    Abstract/FREE Full Text
  4. ↵
    Murayama Y, Nien YL, Duckwiler G, et al. Guglielmi detachable coil embolization of cerebral aneurysms: 11 years’ experience. J Neurosurg 2003;98:959–66
    CrossRefPubMed
  5. ↵
    Murayama Y, Vinuela F, Duckwiler GR, et al. Embolization of incidental cerebral aneurysms by using the Guglielmi detachable coil system. J Neurosurg 1999;90:207–14
    PubMed
  6. Eskridge JM, Song JK. Endovascular embolization of 150 basilar tip aneurysms with Guglielmi detachable coils: results of the Food and Drug Administration multicenter clinical trial. J Neurosurg 1998;89:81–86
    PubMed
  7. Kuether TA, Nesbit GM, Barnwell SL. Clinical and angiographic outcomes, with treatment data, for patients with cerebral aneurysms treated with Guglielmi detachable coils: a single-center experience. Neurosurgery 1998;43:1016–25
    CrossRefPubMed
  8. ↵
    Richling B, Gruber A, Bavinski G, et al. GDC-system embolization for brain aneurysms—location and follow-up. Acta Neurochir (Wien) 1995;134:177–83
    CrossRefPubMed
  9. ↵
    Cognard C, Weill A, Spelle L, et al. Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils. Radiology 1999;212:348–56
    CrossRefPubMed
  10. Byrne JV, Sohn MJ, Molyneux AJ, et al. Five-year experience in using coil embolization for ruptured intracranial aneurysms: outcomes and incidence of late rebleeding. J Neurosurg 1999;90:656–63
    CrossRefPubMed
  11. ↵
    Thornton J, Debrun GM, Aletich VA, et al. Follow-up angiography of intracranial aneurysms treated with endovascular placement of Guglielmi detachable coils. Neurosurgery 2002;50:239–49
    PubMed
  12. ↵
    Fleiss JL. Statistical Methods for Rates and Proportions. New York: Wiley;1981
  13. ↵
    Kundel HL, Polansky M. Measurement of observer agreement. Radiology 2003;228:303–08
    PubMed
  14. ↵
    Molyneux A, Kerr R, Stratton I, et al. International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial. Lancet 2002;360:1267–74
    CrossRefPubMed
  • Received February 7, 2006.
  • Accepted after revision May 4, 2006.
  • Copyright © American Society of Neuroradiology
View Abstract
PreviousNext
Back to top

In this issue

American Journal of Neuroradiology: 28 (3)
American Journal of Neuroradiology
Vol. 28, Issue 3
March 2007
  • Table of Contents
  • Index by author
Advertisement
Print
Download PDF
Email Article

Thank you for your interest in spreading the word on American Journal of Neuroradiology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Observer Agreement in the Assessment of Endovascular Aneurysm Therapy and Aneurysm Recurrence
(Your Name) has sent you a message from American Journal of Neuroradiology
(Your Name) thought you would like to see the American Journal of Neuroradiology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Cite this article
H.J. Cloft, T. Kaufmann, D.F. Kallmes
Observer Agreement in the Assessment of Endovascular Aneurysm Therapy and Aneurysm Recurrence
American Journal of Neuroradiology Mar 2007, 28 (3) 497-500;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
0 Responses
Respond to this article
Share
Bookmark this article
Observer Agreement in the Assessment of Endovascular Aneurysm Therapy and Aneurysm Recurrence
H.J. Cloft, T. Kaufmann, D.F. Kallmes
American Journal of Neuroradiology Mar 2007, 28 (3) 497-500;
del.icio.us logo Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Materials and Methods
    • Results
    • Discussion
    • Conclusions
    • References
  • Figures & Data
  • Info & Metrics
  • Responses
  • References
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Large Neck and Strong Ostium Inflow as the Potential Causes for Delayed Occlusion of Unruptured Sidewall Intracranial Aneurysms Treated by Flow Diverter
  • Factors Influencing Confidence in Diagnostic Ratings and Retreatment Recommendations in Coiled Aneurysms
  • Evaluation of previously embolized intracranial aneurysms: inter-and intra-rater reliability among neurosurgeons and interventional neuroradiologists
  • Patients, not pictures: why complete occlusion may be a complete disaster
  • Inter-rater reliability of published flow diversion occlusion scales
  • Validity of the Meyer Scale for Assessment of Coiled Aneurysms and Aneurysm Recurrence
  • Recurrence, retreatment, and rebleed rates of coiled aneurysms with respect to the Raymond-Roy scale: a meta-analysis
  • Inter- and Intrarater Agreement on the Outcome of Endovascular Treatment of Aneurysms Using MRA
  • Evaluation of the Angiographic Grading Scale in Aneurysms Treated with the WEB Device in 80 Rabbits: Correlation with Histologic Evaluation
  • Follow-up of intracranial aneurysms treated by flow diverter: comparison of three-dimensional time-of-flight MR angiography (3D-TOF-MRA) and contrast-enhanced MR angiography (CE-MRA) sequences with digital subtraction angiography as the gold standard
  • Interobserver variability in the assessment of aneurysm occlusion with the WEB aneurysm embolization system
  • An update to the Raymond-Roy Occlusion Classification of intracranial aneurysms treated with coil embolization
  • Is Visual Evaluation of Aneurysm Coiling a Reliable Study End Point?: Systematic Review and Meta-Analysis
  • Endovascular Treatment of Anterior Communicating Artery Aneurysms: A Systematic Review and Meta-Analysis
  • Stent-Assisted Coiling versus Coiling Alone in Unruptured Intracranial Aneurysms in the Matrix and Platinum Science Trial: Safety, Efficacy, and Mid-Term Outcomes
  • Differences in the Angiographic Evaluation of Coiled Cerebral Aneurysms between a Core Laboratory Reader and Operators: Results of the Cerecyte Coil Trial
  • Observer Variability of an Angiographic Grading Scale Used for the Assessment of Intracranial Aneurysms Treated with Flow-Diverting Stents
  • Standard of practice: embolization of ruptured and unruptured intracranial aneurysms
  • Interobserver Agreement after Pipeline Embolization Device Implantation
  • Interobserver Variability in Retreatment Decisions of Recurrent and Residual Aneurysms
  • Follow-Up of Coiled Intracranial Aneurysms: Comparison of 3D Time-of-Flight MR Angiography at 3T and 1.5T in a Large Prospective Series
  • Cerecyte Coil Trial: Angiographic Outcomes of a Prospective Randomized Trial Comparing Endovascular Coiling of Cerebral Aneurysms With Either Cerecyte or Bare Platinum Coils
  • Outcomes of Endovascular Treatments of Aneurysms: Observer Variability and Implications for Interpreting Case Series and Planning Randomized Trials
  • Residual Flow After Cerebral Aneurysm Coil Occlusion: Diagnostic Accuracy of MR Angiography
  • 1-Hexyl n-cyanoacrylate compound (Neucrylate™ AN), a new berry aneurysm treatment. II. Rabbit implant studies: technique and histology
  • An approach to recurrent aneurysms following endovascular coiling
  • Late Reopening of Adequately Coiled Intracranial Aneurysms: Frequency and Risk Factors in 400 Patients With 440 Aneurysms
  • Observer Agreement Regarding the Necessity of Retreatment of Previously Coiled Recurrent Cerebral Aneurysms
  • Scaling Back on Scales with a Scale of Scales
  • A Prospective Trial of 3T and 1.5T Time-of-Flight and Contrast-Enhanced MR Angiography in the Follow-Up of Coiled Intracranial Aneurysms
  • Evaluation of the Occlusion Status of Coiled Intracranial Aneurysms with MR Angiography at 3T: Is Contrast Enhancement Necessary?
  • MR Angiographic Follow-Up of Intracranial Aneurysms Treated with Detachable Coils: Evaluation of a Blood-Pool Contrast Medium
  • Angiographic and Histologic Comparison of Experimental Aneurysms Embolized with Hydrogel Filaments
  • Ready or Not, Here They Come: Randomized Trials Evaluating New Endovascular Aneurysm Therapies
  • Crossref
  • Google Scholar

This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.

More in this TOC Section

  • SAVE vs. Solumbra Techniques for Thrombectomy
  • CT Perfusion&Reperfusion in Acute Ischemic Stroke
  • Delayed Reperfusion Post-Thrombectomy&Thrombolysis
Show more Interventional

Similar Articles

Advertisement

Indexed Content

  • Current Issue
  • Accepted Manuscripts
  • Article Preview
  • Past Issues
  • Editorials
  • Editors Choice
  • Fellow Journal Club
  • Letters to the Editor

Cases

  • Case Collection
  • Archive - Case of the Week
  • Archive - Case of the Month
  • Archive - Classic Case

Special Collections

  • Special Collections

Resources

  • News and Updates
  • Turn around Times
  • Submit a Manuscript
  • Author Policies
  • Manuscript Submission Guidelines
  • Evidence-Based Medicine Level Guide
  • Publishing Checklists
  • Graphical Abstract Preparation
  • Imaging Protocol Submission
  • Submit a Case
  • Become a Reviewer/Academy of Reviewers
  • Get Peer Review Credit from Publons

Multimedia

  • AJNR Podcast
  • AJNR SCANtastic
  • Video Articles

About Us

  • About AJNR
  • Editorial Board
  • Not an AJNR Subscriber? Join Now
  • Alerts
  • Feedback
  • Advertise with us
  • Librarian Resources
  • Permissions
  • Terms and Conditions

American Society of Neuroradiology

  • Not an ASNR Member? Join Now

© 2025 by the American Society of Neuroradiology All rights, including for text and data mining, AI training, and similar technologies, are reserved.
Print ISSN: 0195-6108 Online ISSN: 1936-959X

Powered by HighWire