Index by author
Boudes, E.
- Pediatric NeuroimagingOpen AccessInjury to the Cerebellum in Term Asphyxiated Newborns Treated with HypothermiaS. Kwan, E. Boudes, G. Gilbert, C. Saint-Martin, S. Albrecht, M. Shevell and P. WintermarkAmerican Journal of Neuroradiology August 2015, 36 (8) 1542-1549; DOI: https://doi.org/10.3174/ajnr.A4326
Branson, H.
- Pediatric NeuroimagingOpen AccessTract-Based Spatial Statistics in Preterm-Born Neonates Predicts Cognitive and Motor Outcomes at 18 MonthsE.G. Duerden, J. Foong, V. Chau, H. Branson, K.J. Poskitt, R.E. Grunau, A. Synnes, J.G. Zwicker and S.P. MillerAmerican Journal of Neuroradiology August 2015, 36 (8) 1565-1571; DOI: https://doi.org/10.3174/ajnr.A4312
Branstetter, B.F.
- Head and Neck ImagingYou have accessResidual Cervical Thymus: A Normal CT Finding That May Be Present Throughout Patients' LivesA.V. Prabhu, H.A. Kale and B.F. BranstetterAmerican Journal of Neuroradiology August 2015, 36 (8) 1525-1528; DOI: https://doi.org/10.3174/ajnr.A4304
Brezova, V.
- Adult BrainOpen AccessHow Does the Accuracy of Intracranial Volume Measurements Affect Normalized Brain Volumes? Sample Size Estimates Based on 966 Subjects from the HUNT MRI CohortT.I. Hansen, V. Brezova, L. Eikenes, A. Håberg and T.R. VangbergAmerican Journal of Neuroradiology August 2015, 36 (8) 1450-1456; DOI: https://doi.org/10.3174/ajnr.A4299
Buchsbaum, J.C.
- FELLOWS' JOURNAL CLUBPediatric NeuroimagingYou have accessRadiation Necrosis in Pediatric Patients with Brain Tumors Treated with Proton RadiotherapyS.F. Kralik, C.Y. Ho, W. Finke, J.C. Buchsbaum, C.P. Haskins and C.-S. ShihAmerican Journal of Neuroradiology August 2015, 36 (8) 1572-1578; DOI: https://doi.org/10.3174/ajnr.A4333
The authors performed a retrospective study on 60 consecutive pediatric patients with primary brain tumors treated with proton radiation therapy. Thirty-one percent of patients developed radiation necrosis with a median time to development of 5 months. They conclude that patients with pediatric brain tumors treated with proton radiation therapy demonstrate a high incidence of radiation necrosis and a short time to development of necrosis. Multiple small areas of necrosis are frequently identified on imaging.
Cao, Y.
- Pediatric NeuroimagingOpen AccessPeriventricular Location as a Risk Factor for Hemorrhage and Severe Clinical Presentation in Pediatric Patients with Untreated Brain Arteriovenous MalformationsL. Ma, Z. Huang, X.-L. Chen, J. Ma, X.-J. Liu, H. Wang, X. Ye, S.-L. Wang, Y. Cao, S. Wang, Y.-L. Zhao and J.-Z. ZhaoAmerican Journal of Neuroradiology August 2015, 36 (8) 1550-1557; DOI: https://doi.org/10.3174/ajnr.A4300
Carone, M.
- Practice PerspectivesYou have accessMesial Temporal Sclerosis: Accuracy of NeuroQuant versus NeuroradiologistM. Azab, M. Carone, S.H. Ying and D.M. YousemAmerican Journal of Neuroradiology August 2015, 36 (8) 1400-1406; DOI: https://doi.org/10.3174/ajnr.A4313
Carrasco, R.
- LetterYou have accessTopographic Diagnosis of Papillary Craniopharyngiomas: The Need for an Accurate MRI-Surgical CorrelationJ.M. Pascual, R. Prieto, I. Castro-Dufourny and R. CarrascoAmerican Journal of Neuroradiology August 2015, 36 (8) E55-E56; DOI: https://doi.org/10.3174/ajnr.A4441
Castro-dufourny, I.
- LetterYou have accessTopographic Diagnosis of Papillary Craniopharyngiomas: The Need for an Accurate MRI-Surgical CorrelationJ.M. Pascual, R. Prieto, I. Castro-Dufourny and R. CarrascoAmerican Journal of Neuroradiology August 2015, 36 (8) E55-E56; DOI: https://doi.org/10.3174/ajnr.A4441
Chakravorty, R.
- EDITOR'S CHOICEAdult BrainYou have accessImproving Multiple Sclerosis Plaque Detection Using a Semiautomated Assistive ApproachJ. van Heerden, D. Rawlinson, A.M. Zhang, R. Chakravorty, M.A. Tacey, P.M. Desmond and F. GaillardAmerican Journal of Neuroradiology August 2015, 36 (8) 1465-1471; DOI: https://doi.org/10.3174/ajnr.A4375
The authors evaluated and validated a semiautomated software platform to facilitate detection of new lesions and improved MS lesions. Two neuroradiologists retrospectively assessed 161 MR imaging comparison study pairs acquired between 2009 and 2011. More comparison study pairs with new lesions and improved lesions were recorded by using the software compared with original radiology reports.