Index by author
Simon, M.
- EDITOR'S CHOICEAdult BrainOpen AccessDual-Layer Detector Cone-Beam CT Angiography for Stroke Assessment: First-in-Human Results (the Next Generation X-ray Imaging System Trial)F. Ståhl, H. Almqvist, J. Kolloch, Å. Aspelin, V. Gontu, E. Hummel, M. van Vlimmeren, M. Simon, A. Thran, Å. Holmberg, M.V. Mazya, M. Söderman and A.F. DelgadoAmerican Journal of Neuroradiology May 2023, 44 (5) 523-529; DOI: https://doi.org/10.3174/ajnr.A7835
Dual-layer detector cone-beam CTA virtual monoenergetic images are noninferior to CTA under certain conditions. Notably, the prototype is hampered by a long scan time and is not capable of contrast media bolus tracking.
Soderman, M.
- EDITOR'S CHOICEAdult BrainOpen AccessDual-Layer Detector Cone-Beam CT Angiography for Stroke Assessment: First-in-Human Results (the Next Generation X-ray Imaging System Trial)F. Ståhl, H. Almqvist, J. Kolloch, Å. Aspelin, V. Gontu, E. Hummel, M. van Vlimmeren, M. Simon, A. Thran, Å. Holmberg, M.V. Mazya, M. Söderman and A.F. DelgadoAmerican Journal of Neuroradiology May 2023, 44 (5) 523-529; DOI: https://doi.org/10.3174/ajnr.A7835
Dual-layer detector cone-beam CTA virtual monoenergetic images are noninferior to CTA under certain conditions. Notably, the prototype is hampered by a long scan time and is not capable of contrast media bolus tracking.
Solnes, L.
- Adult BrainOpen AccessPost-COVID-19 Brain [18F] FDG-PET Findings: A Retrospective Single-Center Study in the United StatesP. Debs, N. Khalili, L. Solnes, A. Al-Zaghal, H.I. Sair, V. Yedavalli and L.P. LunaAmerican Journal of Neuroradiology May 2023, 44 (5) 517-522; DOI: https://doi.org/10.3174/ajnr.A7863
Song, G.
- FELLOWS' JOURNAL CLUBHead & NeckYou have accessA Novel MR Imaging Sequence of 3D-ZOOMit Real Inversion-Recovery Imaging Improves Endolymphatic Hydrops Detection in Patients with Ménière DiseaseJ. Li, L. Sun, N. Hu, L. Li, G. Song, H. Xu, T. Xu, Y. Cheng, L. Xiao, L. Wang, R. Gong and C. LiAmerican Journal of Neuroradiology May 2023, 44 (5) 595-601; DOI: https://doi.org/10.3174/ajnr.A7842
The 3D-ZOOMit real IR sequences are superior to conventional 3D TSE inversion-recovery with real reconstruction sequences in visualizing the endolymphatic space, detecting endolymphatic hydrops, and discovering contrast permeability.
Song, J.
- Adult BrainOpen AccessDWI-Based Radiomics Predicts the Functional Outcome of Endovascular Treatment in Acute Basilar Artery OcclusionX. Zhang, J. Miao, J. Yang, C. Liu, J. Huang, J. Song, D. Xie, C. Yue, W. Kong, J. Hu, W. Luo, S. Liu, F. Li and W. ZiAmerican Journal of Neuroradiology May 2023, 44 (5) 536-542; DOI: https://doi.org/10.3174/ajnr.A7851
Sperre, A.
- EDITOR'S CHOICEPatient SafetyYou have accessProspective Safety Study of Intrathecal Gadobutrol in Different DosesA. Sperre, I. Karsrud, A.H.S. Rodum, A. Lashkarivand, L.M. Valnes, G. Ringstad and P.K. EideAmerican Journal of Neuroradiology May 2023, 44 (5) 511-516; DOI: https://doi.org/10.3174/ajnr.A7841
The present study adds to the accumulating evidence that intrathecal gadobutrol in doses up to 0.50 mmol is safe.
Srinivasan, D.
- FunctionalOpen AccessIntensive Blood Pressure Management Preserves Functional Connectivity in Patients with Hypertension from the Systolic Blood Pressure Intervention Randomized TrialC. Shah, D. Srinivasan, G. Erus, M. Kurella Tamura, M. Habes, J.A. Detre, W.E. Haley, A.J. Lerner, C.B. Wright, J.T. Wright, S. Oparil, S.B. Kritchevsky, H.A. Punzi, A. Rastogi, R. Malhotra, C.H. Still, J.D. Williamson, R.N. Bryan, Y. Fan and I.M. NasrallahAmerican Journal of Neuroradiology May 2023, 44 (5) 582-588; DOI: https://doi.org/10.3174/ajnr.A7852
Stahl, F.
- EDITOR'S CHOICEAdult BrainOpen AccessDual-Layer Detector Cone-Beam CT Angiography for Stroke Assessment: First-in-Human Results (the Next Generation X-ray Imaging System Trial)F. Ståhl, H. Almqvist, J. Kolloch, Å. Aspelin, V. Gontu, E. Hummel, M. van Vlimmeren, M. Simon, A. Thran, Å. Holmberg, M.V. Mazya, M. Söderman and A.F. DelgadoAmerican Journal of Neuroradiology May 2023, 44 (5) 523-529; DOI: https://doi.org/10.3174/ajnr.A7835
Dual-layer detector cone-beam CTA virtual monoenergetic images are noninferior to CTA under certain conditions. Notably, the prototype is hampered by a long scan time and is not capable of contrast media bolus tracking.
Still, C.H.
- FunctionalOpen AccessIntensive Blood Pressure Management Preserves Functional Connectivity in Patients with Hypertension from the Systolic Blood Pressure Intervention Randomized TrialC. Shah, D. Srinivasan, G. Erus, M. Kurella Tamura, M. Habes, J.A. Detre, W.E. Haley, A.J. Lerner, C.B. Wright, J.T. Wright, S. Oparil, S.B. Kritchevsky, H.A. Punzi, A. Rastogi, R. Malhotra, C.H. Still, J.D. Williamson, R.N. Bryan, Y. Fan and I.M. NasrallahAmerican Journal of Neuroradiology May 2023, 44 (5) 582-588; DOI: https://doi.org/10.3174/ajnr.A7852
Sun, L.
- FELLOWS' JOURNAL CLUBHead & NeckYou have accessA Novel MR Imaging Sequence of 3D-ZOOMit Real Inversion-Recovery Imaging Improves Endolymphatic Hydrops Detection in Patients with Ménière DiseaseJ. Li, L. Sun, N. Hu, L. Li, G. Song, H. Xu, T. Xu, Y. Cheng, L. Xiao, L. Wang, R. Gong and C. LiAmerican Journal of Neuroradiology May 2023, 44 (5) 595-601; DOI: https://doi.org/10.3174/ajnr.A7842
The 3D-ZOOMit real IR sequences are superior to conventional 3D TSE inversion-recovery with real reconstruction sequences in visualizing the endolymphatic space, detecting endolymphatic hydrops, and discovering contrast permeability.